H. STEAM INFORMATION

It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the steam plumbing installation is adequate and conforms with local and state regulations or codes.

IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in

component failure, which will VOID THE WARRANTY.

NOTE: This dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of air of 0.75 cfh @ 80 psi +/- 10 psi (5.51 bar +/- 0.69 bar).

1.Steam Coil pH Level

The normal pH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel type steam coils the pH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit the acid attack of the steam coils.

IMPORTANT: Coil failure due to improper pH level will VOID THE WARRANTY.

2.Steam Requirements - High Pressure

Inlet ------ 1” supply line connection --- qty. one (1) at top manifold. Return ---- 1” return line connection --- qty. one (1) at bottom manifold.

Operating Steam Pressure

Maximum

125 psig*

 

861.84 kPa

 

 

 

 

Heat Input (Normal Load)

 

7 Bhp

 

 

 

 

Consumption (Approximate)

238.7 lb/hr

 

108.3 kg/hr

 

 

 

 

Shaded areas are stated in metric equivalents

*The minimum operating pressure for optimum results is 100 psig (689.47 kPa).

3.Installation Instructions

To ensure an adequate supply of steam is provided, be sure that the steam supply lines and steam return lines are sized and laid out as stipulated in this manual. Inadequate steam supply lines and steam return lines or improper steam plumbing will result in poor performance and can cause component failure. Clean, dry steam must be provided to the dryer.

IMPORTANT: Steam coil failure due to water hammer by wet steam will VOID THE WARRANTY.

27

Page 31
Image 31
American Dryer Corp ML-75V installation manual Operating Steam Pressure, Steam Information