ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

 

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

PHASE

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

WIRE SIZE

BREAKER

 

 

 

60 Hz

50 Hz

 

Time Delay

 

120

1 ø

2

13.0

*

20

2 0

208

1 ø

2

7.6

*

1 5

15

220

1 ø

2

7.3

8.6

*

1 5

15

230

1 ø

2

8.0

*

1 5

15

240

1 ø

2

7.0

*

1 5

15

208

3

4.7

*

1 5

15

230

3

4.7

*

1 5

15

240

3

4.9

*

1 5

15

380

3

2.9

*

1 5

15

380

4**

3.1

*

15

15

400

4**

3.2

*

15

15

416

4**

3.1

*

15

15

460/480

3

2.8

*

15

15

* AWG Stranded Wire Type - size wire as per National Electrical Code or local codes.

** 3-Wire available.

 

 

 

 

 

5/26/05

b. Electric Models Only

ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data label. The connecting wires must be properly sized to handle the rated current.

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

60 Hz

50 Hz

 

 

MINIMUM WIRE SIZE

FUSING

Dual Element Time Delay

CIRCUIT BREAKER

 

 

 

30 kW

 

 

 

208

3

9 1

*

125

125

230

3

8 3

*

125

125

240

3

7 9

*

100

100

380

3

48

*

60

6 0

380

4**

54

*

70

70

400

4**

51

*

70

70

416

4**

50

*

70

70

460

3

40

*

50

50

480

3

39

*

50

50

575

3

33

*

50

50

 

 

 

36 kW

 

 

 

208

3

108

*

150

150

230

3

98

*

125

125

240

3

94

*

125

125

380

3

58

*

80

80

380

4**

63

*

80

80

400

4**

60

*

80

80

416

4**

58

*

80

80

460

3

48

*

60

60

480

3

46

*

60

60

* AWG Stranded Wire Type - size wire as per National Electrical Code or local codes.

** 3-Wire available.

 

 

 

 

 

5/26/05

19

Page 23
Image 23
American Dryer Corp ML-75V installation manual Gas and Steam Models Only