NOTE: Water column (W.C.) pressure requirements (measured at the gas valve pressure tap);
Natural Gas | 3.5 inches Water Column |
L.P. (Liquid Propane) Gas .... | 10.5 inches Water Column |
IMPORTANT: There is no regulator provided in a L.P. dryer. The water column (W.C.) pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
a.Microprocessor (computer) Dryer Models
1)Spin and stop times are not adjustable in the Automatic Mode and have been preprogrammed into the microprocessor controller (computer) for a
2)Spin and stop times are adjustable in the Manual (timed) Mode.
J.OPERATING INSTRUCTIONS
NOTE: Before attempting to start the dryer make sure the main door is closed and the lint drawer is securely in place.
1.To start the dryer:
a. Microprocessor (computer) Dryers
1.Display will read "READY" (meaning no cycle in progress).
2.Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., Key "E"). Dryer will start to rotate.
3.L.E.D. (light emitting diode) display will now toggle "Drying" "Manual" "Cycle E" "30 Min" "Remain" meaning the dryer is in the drying cycle and count down in minutes.
NOTE: Pressing touch pad key "A," "B," "C," "D," and "F" will also start the dryer. The six (6) preprogrammed drying cycles ("A" through "F") have been stored in the microprocessor (computer's) memory. Refer to the Computer Programming Manual supplied with dryer for more specific operating information.
NOTE: The dryer can be stopped at any time by opening main door or by pressing the "STOP" key. The restart the dryer, press the "START" key or preprogrammed cycle key (i.e., "E").
NOTE: Selection (setting) changes can be made at any time during the drying cycle by pressing the "CLEAR/STOP" key twice. The L.E.D. (light emitting diode) display will return to "READY" at which time a new cycle selection can be made.
26