2.Electrical Service Specifications

M L G - 9 6 H S

ELECTRIC AL SERVIC E SPECIFIC ATION S (PER DRYER)*

SERVICE

 

WIRE

MINIMUM

APPROX.

CIRCUIT

PHASE

AMP DRAW

BREAKER

VOLTAGE

SERVICE

WIRE SIZE**

 

 

 

 

 

60 Hz

50 Hz

60 Hz

50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

2 0 8

3 ø

3/4

12

13

.5

--

25

--

2 4 0

3 ø

3

12

12

.5

--

25

--

3 8 0 - 4 0 0

3 ø

3/4

14

--

6.9

--

15

416

3 ø

3/4

14

--

6.6

--

15

460/480

3 ø

3/4

14

6.

8

--

15

--

*Contact factory for information not listed.

**AWG Stranded Type Wire...for individual lenghts less than 100 feet. (Motor lead wire is recommanded.)

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the back side of the upper or top control door. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.