Code

Cause

Remedy

 

 

 

 

Abnormal drop in power supply voltage, or power

Turn off the power and check the input voltage. After

E.90

was turned on again immediately after it was

turning off the power, wait 3 seconds or more before

 

turned off.

turning it on again.

E.91

Abnormal rise in power supply voltage.

Turn off the power and check the input voltage.

 

 

 

E.A0

Starting switch was pressed without any valid

Re-read the sewing data.

sewing data loaded.

 

 

E.A1

Home position point was not detected within a

Turn off the power and check the X-Y feed and the

certain time during home position detection.

home position sensor connection.

 

 

 

 

E.c0

Motor PROM is not correctly inserted.

Turn off the power and check.

E.c1

The box cooling fan (at the left when looking from

Turn off the power and check whether any thread

the front) is not operating.

scraps have built up.

 

E.c2

Heat shink of control circuit board is abnormally

Turn off the power and clean the air intake port of the

hot.

box.

 

E.c3

Abnormal current detected in X pulse motor.

Turn off the power and contact a qualified service

technician.

 

 

E.c4

dAbnormal current detected in X pulse motor.

Turn off the power and contact a qualified service

technician.

 

 

E.c5

The box cooling fan (at the right when looking

Turn off the power and check whether any thread

from the front) is not operating.

scraps have built up.

 

 

 

 

E.d0

Air pressure drop error.

Turn off the power and check.

 

 

 

E.E0

Main PROM is not correctly inserted.

Turn off the power and check.

E.E1

Communication error detected by control circuit

Turn off the power, wait a while and then turn it back

board.

on.

 

E.E2

Communication error detected by panel circuit

Turn off the power, wait a while and then turn it back

board.

on.

 

E.E3

Bad connection in cable between panel and box.

Turn off the power and check.

 

 

 

E.F0

Power relay is not operating (malfunction of

Turn off the power and contact a qualified service

power supply circuit board).

technician.

 

E.F1

Bad connection in cable between power supply

Turn off the power and check.

circuit board and main circuit board.

 

 

E.F2

Abnormal current detected in power supply circuit

Turn off the power and contact a qualified service

board.

technician.

 

 

 

 