■DIP switch D

Chapter 6 Power supply and electrical parts adjustment

DIP switch D

SW No.

When ON

D-1

The first two stitches at the sewing start will be sewn at low speed (approx. 260 spm).

 

 

D-2

The last two stitches at the sewing end will be sewn at low speed (approx. 260 spm).

 

 

D-3

----------------

 

 

D-4

The last two stitches at the sewing end will be sewn at low speed (approx. 700 spm).

 

 

D-5

----------------

 

 

D-6

Slow-speed sewing at the sewing start will be canceled.

 

 

D-7

When the upper shaft is stopped, the motor will change direction and the needle bar will return to the

vicinity of the needle up stop position.

 

 

 

D-8

During an emergency stop, the thread is trimmed and the needle bar stops in the raised position.