Chapter 7

Error status

 

Probable causes

Check/repair/adjust

Parts to be replaced

 

 

 

 

 

 

1.

With error code [E.12], the

• Check that connector P3 (HEAD) on the control

EM switch

 

 

emergency stop switch is

circuit board is securely inserted and the

assembly

 

 

activated, or it is defective.

emergency stop switch is correctly wired.

 

 

 

 

 

 

 

2.

With error code [E.21], the

• Check that grounding is securely made and there

Control circuit

 

 

machine is malfunctioning.

is no equipment that generates strong electrical

board

 

 

 

noise nearby.

 

 

 

 

 

 

 

3.

With error code [E.60], the panel

• Turn on the power again. If nothing changes,

Panel circuit

 

 

circuit board is defective.

panel PCB is defective.

board

 

 

 

 

 

 

4.

With error code [E.61], the

• Turn on the power again. If nothing changes,

Control circuit

 

control circuit board is defective.

control PCB is defective.

board

 

 

 

 

 

 

 

 

 

 

5.

With error code [E.90], the power

• Check that the voltage of a socket is within ±10%

 

 

 

supply voltage has sharply

of specified voltage.

 

 

 

dropped.

• Refer to #d1-1, -1, -3

 

 

 

 

 

 

#1 The

6.

With error code [E.91], the power

• Refer to #1.1-5

 

 

supply voltage has sharply risen.

 

 

power

 

 

 

 

 

 

 

lamp does

 

 

 

 

not light

 

 

 

 

whenthe

 

 

 

 

7.

With error code [E.c0], the [MT]

• Refer to #1.1-13

PROM

power is

turned on.

 

PROM on the control circuit

 

 

 

 

board is defective.

 

 

 

 

 

 

 

 

8.

With error code [E.c1], the box

• Check whether any thread scraps are not

Fan motor

 

 

cooling fan (at the left when

entangled in the cooling fan.

assembly

 

 

viewed from the front) is

• Check that connector P10 (FAN-R) on the control

 

 

 

defective.

circuit board is securely inserted.

 

 

 

 

 

 

 

9.

With error code [E.c2], the

• Clean the air intake of the control box.

Control circuit

 

 

control box has overheated.

• The temperature detector is screwed into the

board

 

 

 

heatsink on the control circuit board. Turn on the

 

 

 

 

power after the temperature of the heatsink falls.

 

 

 

 

If the error still appears, the control circuit board

 

 

 

 

is defective.

 

 

 

 

• Note: If the machine is operating with the control

 

 

 

 

box open, the heatsink will overheat, resultantly,

 

 

 

 

error [E.c2] will occur.

 

10. With error code [E.c3],

• Check that connector P7 (XPM) on the control

X pulse motor

overcurrent has occurred in X-

circuit board is securely inserted and the X-pulse

control circuit

pulse motor.

motor is securely plugged in.

board

 

• Refer to #1.1-2

 