Brother BAS-311E service manual Power supply and electrical parts adjustment

Models: BAS-311E

1 150
Download 150 pages 53.38 Kb
Page 97
Image 97
Manual background

Chapter 6 Power supply and electrical parts adjustment

Turn the dial while pressing the STEP BACK switch to change the values.

Turn the dial while pressing the STEP BACK switch to change the values.

SW No.

Possible setting

Units

range

 

 

memo-30

1 - 999

x 10ms

memo-31

1 - 4

----

memo-321 - 7 ----

Initial

 

Explanation

 

value

 

 

 

 

 

10

Time until feed mechanism starts moving after

work clamp has lifted.

 

 

 

1

Changes the feed speed. 1 (Fast)

4 (Slow)

 

Changes the possible sewing speed for a given stitch length.

 

1 (Fast)

7 (Slow)

 

 

1 (2,700/3 mm), 2 (2,600/3 mm), 3(2,500/3 mm),

34 (2,300/3 mm), 5 (2,000/3 mm), 6 (1,800/3 mm),

7 (1,200/3 mm)

Settings 1 and 2 are outside the warranty specification at the time of shipment from the factory.)

memo-33

1 - 10

x 7.5°

memo-34

1 - 5

----

memo-35

10

- 60

Xms

memo-36

1

- 3

----

memo-37

0

- 3

----

memo-38

1- 20

X0.1S

memo-39 0 - 11 ----

5

Changes the feed timing

 

 

1 (Fast)

5 (standard)

10 (Slow)

 

 

 

0

Number of stitches sewn at 400 spm (10W speed) at sewing

start

 

 

 

 

 

 

 

 

Solenoid ON time changes when work clamp is being

40

lowered (solenoid specifications only)

 

10

60

 

 

 

 

 

 

(Quiet)

(High work clamp capacity)

 

 

Solenoid ON time to raise presser foot is changed.

 

1

(Standard) 1

3 (Upper limit)

 

ç

 

1 (10 ms) 2 (20 ms) 3 (30 ms)

 

 

 

Gear ratio is automatically corrected when 2DD data is read.

 

0: Follows the model specified in DIP switch C.

 

 

1: Reads 2DD data as 311A data.

 

 

3

2: Reads 2DD data as 326A data.

 

 

3: Reads 2DD data as 341A/342A data.

 

 

 

 

[This function is available when panel PROM indication is

 

 

PL-C or later.]

 

 

 

1

Delay time from the point when the cassette is

 

clamped to the start of sewing when DIP switch A7 is

Î

 

ON during automatic sewing

 

 

[Set value]

0: Sensor home position, 1: Center of sewing area, 2: Upper

left of sewing area, 3: Lower left of sewing area, 4: Upper

right of sewing area, 5: Lower right of sewing area, 6:

Sewing start point, 7: Sewing end point, 8: Upper left of

mask, 9: Lower left of mask, 10: Upper right of mask, 11: Lower right of mask

[Procedure]

1.Select memory switch 39.

0 2. Change X and Y scales.

3.Step on start switch to return to home position, and sewing data can be created with specified scales.

[Mask]

¡Mask is a rectangular frame

Upper left

of mask

to cover the rounded edges

 

of sewing data.

 

¡In the left figure, an oval is

Lower left

sewing

data, and the

of mask

rectangle

indicated with a

 

broken line is the mask.

Note:Ç · Î · Ï indicates that these functions are available for software versions MN-C · MND · MN-F or later.

BAS-311E.311EL.326E.326EL

89

Page 97
Image 97