8. Checking the input voltage

Chapter 6 Power supply and electrical parts adjustment

8. Checking the input voltage

1.Turn on the power switch.

2.Press the MENU switchq until the X-SCALE indicator w is lit.

SPLITプリッNON. .�

SPLITX-SCALEN.

qw

3. While pressing the TEST switch e, press the R/W switch r.

横倍率

X-SCALE

スト

TEST

e

/

R / W

r

4. If the input voltage is normal, the input voltage conditions will be shown in the display as shown below.

200-V specifications

090 - 110

 

 

 

"100" is displayed when the input voltage is 200 V.

220-V specifications

100 - 120

 

 

 

 

230-V specifications

105 - 125

 

 

 

"110" is displayed when the input voltage is 100 V (for 100-V

100-V , 380-V , 400-V and

 

100 - 120

specs.), 380 V (for 380-V specs.) or 415 V (for 415-V specs.).

415-V specifications

 

 

 

 

 

 

5. Press the TEST switch e once more to return the display to the normal condition.

9. Clearing all memory settings

¡If the sewing machine stops operating normally, the cause may be that an incorrect memory setting has been made by means of the memory switch, for instance. In this case, carry out the following procedure to clear the memory, and also check the DIP switch settings.

While pressing the R/W switch, turn on the power. This will clear all of the memory settings.

/