Brother BAS-311E Checking the input sensor and DIP switch input, BAS-300E series, Off Off

Models: BAS-311E

1 150
Download 150 pages 53.38 Kb
Page 98
Image 98
7. Checking the input sensor and DIP switch input

Chapter 6 Power supply and electrical parts adjustment

SW No.

Possible setting

Units

Initial

Explanation

range

value

 

 

 

 

 

 

 

 

memo-3A

1-3

----

2

Change speed limit by stitch length.

 

 

 

 

 

(Max. speed remains same)

 

 

 

 

1:Speed limit by stitch length is up,sewing speed increases.

 

 

 

 

2:Standard

 

 

 

 

3:Speed limit by stitch length is down, sewing speed

 

 

 

 

decreases.

 

 

 

 

* In case drifting problem occurs at a part of large stitch

 

 

 

 

length, select 3.

 

 

 

 

* If you select 1, Please be careful because drifting might Ï

 

 

 

 

occur depending on sewing condition.

 

 

 

 

 

memo-3B -

----

----

0

----

memo-3F

 

 

 

 

 

 

 

 

 

7. Checking the input sensor and DIP switch input

 

 

t

 

 

BAS-300E series

プログラNO.

 

 

メニュー

PROGRAM NO.

 

MENU

 

r

横倍率

u

X-SCALE

 

 

縦倍率

 

 

Y-SCALE

 

 

スピード

 

 

SPEED

 

 

下糸カウンター

 

 

B.T. COUNTER

/

q

スプリットN.�

R / W

 

SPLIT N.

e

 

 

 

 

y

電 源

POWERA

下糸設定下糸交換

B.T. SET

B.T. CHANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

テスト

 

ップバック

 

B

 

 

TEST

 

STEP BACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

w

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8BAS-300E series

OFF

OFF

1.When the SPLIT NO. indicator q is lit and the R/W switch e is pressed while the TEST switch w is being pressed, the X-SCALE indicator r will be lit and the state of the X home position signal will appear on the display t.

■ When sensor is ON

■ When sensor is OFF OFF

2.Each time the MENU switch y is pressed, a different indicator will illuminate and the operating condition for the corresponding item will appear on the display.

¡When X-SCALE indicator is lit

:

X home position sensor

¡When Y-SCALE indicator is lit

:

Y home position sensor

¡When SPEED indicator is lit

:

Needle up signal (synchronizer)

¡When B.T. COUNTER indicator is lit

:

24-split signal (synchronizer)

¡When SPLIT ON. indicator is lit

:

Needle down signal (synchronizer)

3.If the settings for DIP switch A at the side of the operation panel are changed at this time, the changed switch number will appear in the left digit of the PROGRAM NO. display u.

4.If the settings for DIP switch B are changed at this time, the changed switch number will appear in the right digit of the PROGRAM NO. display u.

90

BAS-311E.311EL.326E.326EL

Page 98
Image 98
Brother BAS-311E Checking the input sensor and DIP switch input, Power supply and electrical parts adjustment, Off Off