#1.2

Chapter 7

Error status

 

Probable cause

Check/repair/adjust

Parts to be replaced

 

 

 

 

 

11. With error code [E.c4],

• Check that connector P6 (YPM) on the control

Y pulse motor

 

 

overcurrent has occurred in Y-

circuit board is securely inserted and the Y-pulse

control circuit

 

 

pulse motor.

motor is correctly wired.

board.

 

 

 

• Refer to #1.1-2

 

 

 

 

 

 

12. With error code [E.c5], the box

• Refer to #1.1-8 [E.CI]

Fan motor

 

 

cooling fan (at the right when

• Check that connector P25 (FAN-L) on the control

assembly

 

 

viewed from the front) is

circuit board is securely inserted.

 

 

 

defective.

 

 

 

 

 

 

 

 

13.

With error code [E.E0], the [MN]

• Check that the PROM of the control circuit board

PRON

 

 

PROM on the control circuit

is securely inserted and its leads are not bend.

 

 

 

board is defective.

• Check that MN and MT of the PROM are matching

 

 

 

 

those on the main PCB.

 

#1 The

 

 

 

 

power

 

 

 

 

lamp does

 

 

 

 

not light

 

 

• If the PROM has no problem, check the

Panel code

 

 

connection between pin 3 in connector P18

 

when the

 

 

 

power is

 

 

(PANEL) on the control circuit board and pin 5 in

 

turned on.

 

 

connector P5 (DRV) on the panel PCB.

 

 

 

 

 

 

 

14.

With error code [E.F0], the relay

• Check that the PER code is securely inserted (refer

Power PCB

 

 

on the power PCB is not

to #1.1-15). If the error appears, replace the

 

 

 

working.

power PCB with a new one.

 

 

 

 

 

 

 

15.

With error code [E.F1], the cord

• Check that connector P2 (PER) of the power PCB

PER code.

 

 

is not securely inserted.

and connector P20 (PER) on the main PCB are

 

 

 

 

securely inserted. Check there is no damage in

 

 

 

 

wiring.

 

 

 

 

 

 

 

16.

With error code [E.F2],

• Find a cause of noise. (Refer to #1.1-2.)

Power PCB

 

 

overcurrent has occurred in

• Replace the power PCB . (Refer to #1.1-14.)

 

 

 

power PCB.

 

 

 

 

 

 

 

 

1.

Panel PCB is not correctly

• Check whether the panel setting plate makes

 

 

 

attached.

contact with a switch.

 

#1.2

 

 

 

 

No

 

 

 

 

 

 

 

 

switches

2.

Panel PCB is defective.

• Refer to #1-7

Panel circuit

on the

 

 

 

board

panel are

 

 

 

 

 

 

 

not

 

 

 

 

activated.

 

 

 

 

3.

Programmer detective.

• Pull out the programmer. If a switch is activated,

Programmer

 

 

 

 

the programmer is defective.

 

 

 

 

 

 

#2

1.

With error code [E.40], the cord

• Check the connections and pins between

FDD Harness

If the R/W

 

or the floppy disk drive (FDD) is

connector P1 on the panel PCB and the FDD, and

 

switch is

 

defective.

between connectors CH1 and CH2 on the panel

 

pressed,

 

 

PCB and the FDD.

 

the

 

 

• Replace the floppy disk drive.

Floppy disk drive

indicator

 

 

 

 

lamp is not

 

 

 

 

lit and an

 

 

 

 

error code

 

 

 

 

appears.

 

 

 

 

 

 

 

 

 

BAS-311E.311EL.326E.326EL

105

Page 113
Image 113
Brother BAS-311E service manual Chapter, switches, pressed, #1.2