Chapter 6 Power supply and electrical parts adjustment

Chapter 6 Power supply and electrical parts adjustment

Chapter 6 Power supply and electrical parts adjustment

1. Precautions at the time of adjustment

Pay attention to the following when opening the control box for maintenance.

Electric shock

Some large capacitors may have a high voltage remaining in them for up to 5 minutes after the power is turned off. To prevent electric shock, wait at least 5 minutes after the power is turned off before doing the following:

Opening and closing the control box

Replacing fuses

Separating and joining connectors

measuring resistance

Doing anything with a possibility of touching something inside the control box

Some adjustments require measuring the voltage while the power is turned on with the control box kept open.

In such a case, be careful not to touch any place other than that for the measurement. In addition, always keep in mind that a high voltage remains for 5 minutes after the power is turned off.

Injury

While the power is turned on, the cooling fan of the control box operates; be careful not to get caught in it.

When separating or rejoining connectors, and measuring something, be careful not to cut your fingers on metal parts such as heatsinks and covers.

2. Components inside the control box

The following are brief explanations of components inside the control box. See control circuit block diagram at the end of this manual for the details of the connections.

Main PCB

The main PCB is fixed to the rear panel of the control box. This PCB serves to control machine operation.

Power supply circuit board

The power supply circuit board is fixed at the bottom of the control box. Four fuses are mounted on this PCB.

Panel circuit board

The panel circuit board is fixed to the front panel of the control box. This PCB controls indications of the machine status and the input operation.

DC fan motor

The DC fan motor serves as a fan to cool the inside of the control box. Clean the inlet filter monthly.

Conversion transformer (depending on power supply voltage specification)

The conversion transformer controls the power supply voltage to provide 220 V.

Operation panel
Control box

Panel circuit board

Conversion transformer

 

 

DC fan

 

Inlee fileer

3.5 FDD

Power supply

circuit board

Main PCB

 

BAS-311E.311EL.326E.326EL

73