After a few

Chapter 7

Error status

 

 

 

Probable causes

Check/repair/adjust

Parts to be replaced

 

 

 

 

 

 

 

 

 

1. With error code [E.40], a floppy

• When a floppy disk is inserted into the FDD, check

Drive device

 

 

 

 

disk is not inserted.

the sound of the motor.

 

#3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After a few

 

2.

With error code [E.41] or [E.4F],

• When error code [E.40], [E.41], or [E.4F] appears,

Floppy

seconds

 

after the

 

 

the floppy disk is defective.

insert other floppy disk into the FDD.

 

R/W switch

 

 

 

 

 

 

 

 

 

If the FDD reads the floppy disk, the original disk

 

is pressed,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is defective.

 

an error

 

 

 

 

 

 

 

 

 

 

code

 

 

 

 

 

 

 

 

 

 

 

appears.

 

 

 

 

 

 

 

 

 

 

 

 

3.

Panel circuit board defective

 

Panel circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

board

 

 

 

 

 

 

 

 

 

 

1.

Foot switch and code defective

(Make sure that the power is turned off.)

Foot switch

 

 

 

 

 

 

 

 

 

 

 

• Remove the connector for foot switch connected

 

 

 

 

1 - 2 Presser foot

 

 

 

to the outside of the control box, and check the

 

 

 

 

 

 

 

continuity between pins 1 and 2, and pins 7 and 8

 

 

 

 

 

 

 

 

Connector on the co

rd

 

 

 

 

 

 

 

 

in the connector on the cord. (For pneumatic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specification, check the continuity between pins 3

 

 

 

 

 

 

 

 

 

 

 

 

and 4.)

 

 

 

 

 

 

 

 

 

 

 

 

The continuity in each case should be normally ∞

 

 

 

 

 

 

 

 

 

 

 

 

Ω or 0 Ω when the switch is stepped on.

 

 

 

 

 

 

 

 

 

 

 

 

7 - 8 Start

 

 

 

 

 

 

 

 

 

 

 

 

3

- 4 Second switch

Presser

 

 

 

 

 

 

 

 

 

(Pneumatic only)

 

 

 

 

#4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Any cord in the control box is

• Insert the connector checked above, open the

Foot switch code

The work

 

clamp does

 

 

defective.

 

 

 

control box, and check the continuity between

assembly

 

 

 

 

 

 

not move

 

 

 

 

 

 

 

 

 

pins 1 and 2, pins 3 and 4, pins 5 and 6 in

 

up and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connector P19 (FOOT) on the PCB.

 

down

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Without removing the connector, put a tester

 

when the

 

 

 

 

 

 

 

 

 

 

foot switch

 

 

 

 

 

 

 

 

 

from the lead side.)

 

is stepped

 

 

 

 

 

 

 

 

 

The continuity in each case should be normally ∞

 

on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ω or 0 Ω when the switch is stepped on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

 

Presser

Second switch

 

 

 

 

 

 

 

 

foot

Presser

 

 

 

 

 

 

 

 

 

 

(Pneumatic only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Fuse blown

 

 

 

• Remove fuse no.1 and check the continuity.

(Quick melting

 

 

 

 

 

 

 

 

 

 

 

(If there is no continuity, go to the next item.)

type 5A-250V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

106

BAS-311E.311EL.326E.326EL

Page 114
Image 114
Brother BAS-311E service manual Chapter, After a few, Presser