Error status

Probable causes

Check/repair/adjust

Parts to be replaced

 

 

 

 

 

4. Fuse has blown

• Remove fuses No.3 and No.4, and check them for

Fuse 6A-250A

 

 

continuity.

 

 

 

If there is no continuity, replace the fuses with new

 

 

 

ones, and perform the check/repair/adjust items of

 

 

 

#1-5.

 

5. Power supply circuit board

• Separate P4 (ACIN) connectors on the power supply

Power supply

defective

circuit board, and then measure the resistance

circuit board

 

between the followin oth cases, the power supply

 

 

circuit board is not defective.

 

 

• Measure the resistance between pins 1 and 2.

 

 

If there is not short, the power supply circuit board is

 

 

not defective.

 

 

• rejoin P4 (ACIN) connectors on the power supply

 

 

circuit board.

 

 

Separate P3 (POWER) connectors on the main circuit

 

 

board, turn on the power, and measure the voltage

 

 

across pins 1 and 3 in the connector on the cable.

 

 

If it is + 5V, the power circuit board is not defective.

 

 

After measurement, turn off the power wait at least 5

 

 

minutes, and then rejoin P3 connectors.

 

#1

continued

6. Control circuit board defective

• With P3 (POWER) connectors plugged in on the

Control circuit

 

control circuit board, turn on the power, and measure

board

 

the voltage across pins 1 and 3 in the connector on

 

 

the cable.

 

 

If it is + 5V, the power circuit board is not defective.

 

 

After measurement, turn off the power.

 

7. Panel circuit board defective

Check that P18 (PANEL) connectors of the main circuit board and P5 (DRV) connectors of the panel circuit board are plugged in.

Panel circuit board

BAS-311E.311EL.326E.326EL