Chapter 7

Error status

 

 

Probable causes

Check/repair/adjust

Parts to be replaced

 

 

 

 

 

#17

1.

The synchronizer is not properly

• If the needle stop position varies at random every

The

 

 

adjusted.

time the machine operation is complete, adjust

 

machine

 

 

 

the needle stop position to the upper position.

 

does not

 

 

 

 

 

stop with

 

 

 

 

 

the needle

 

 

 

 

 

at the upper

 

 

 

 

 

 

 

 

 

Control circuit

position.

2.

 

Control circuit board defective

 

board.

 

 

 

 

 

 

 

 

#18

 

• Refer to #8-1, 2, 3, 4.

The

 

machine

 

 

 

 

 

can not

 

 

 

 

 

sew

 

 

 

 

 

patterns as

 

 

 

 

 

pro-

 

 

 

 

 

grammed.

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

EM switch defective.

• Remove connector P3 (HEAD) on the control

EM switch

#19

 

 

 

circuit board, and check the continuity on the

assembly.

 

 

 

cord.

 

The

 

 

 

 

 

 

 

Between pins 1 and 2:

 

operation

 

 

 

 

 

 

 

0 Ω normally or ∞ Ω when the emergency

 

will not stop

 

 

 

 

 

 

 

stop switch is pressed.

 

if the

 

 

 

 

 

 

 

Between pins 2 and 3: ∞ Ωnormally or 0 Ω

 

emergency

 

 

 

 

 

 

 

when the emergency stop switch is pressed.

 

stop switch

 

 

 

 

 

 

 

 

 

is pressed.

 

 

 

 

 

 

 

 

 

 

 

#20

 

• Refer to #16, #17

The thread

 

trimmer

 

 

 

 

 

does not

 

 

 

 

 

operate

 

 

 

 

 

after the

 

 

 

 

 

emergency

 

 

 

 

 

stop switch

 

 

 

 

 

is canceled.

 

 

 

 

 

 

 

 

 

 

 

#21

1.

 

Panel circuit board defective

• Refer to #1 and #2 (panel switch).

Panel circuit board

 

 

 

 

 

The STEP

 

 

 

 

 

BACK

 

 

 

 

 

switch is

 

 

 

 

 

inoperative.

 

 

 

 

 

 

 

 

 

 

 

 

• Refer to #8-1, 2, 3, 4 and #13, #14.

#22

 

 

 

 

 

Sewing is

 

 

 

 

 

not

 

 

 

 

 

resumed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Remove connector P2 (PGM) on the panel PCB

 

 

1.

The programmer connector and

and connector P2 on the programmer PCB, and

#23

 

 

its cable are defective.

then return them to their positions.

 

 

 

 

 

 

Programmi

2.

 

The programmer is defective.

• Replace the programmer with a new one.

Programmer

ng can not

 

 

 

 

 

 

be made.

 

 

 

 

 

3.

 

Panel circuit, board defective

• Replace the panel circuit board with a new one.

Panel circuit board

 

 

 

 

 

 

 

 