American Dynamics VII manual Take a closer look, Two Mounting Base Options

Models: VII

1 4
Download 4 pages 19.52 Kb
Page 3
Image 3

take a closer look

On-screen text supports six languages: English, French, Italian, Spanish, German and Portuguese.

Password protection prevents unauthorized use of the configuration utility.

The dome incorporates an innovative twist lock release from the mounting base for easy installation and servicing.

The fully isolated power supply helps eliminate ground loops.

Users can set line-lock on or off. Line-lock is enabled to help prevent vertical rolling in multi-camera applications.

Vertical sync phase adjustment is provided to help compensate for different phases of power when line-lock is enabled, making it ideal for single and multi-phase power installations.

Sensing of 50/60 Hz lines is automatic and does not require manual adjustment.

Surge protection is provided for video, code, alarms and power connections.

Daisy chain configuration of control wiring is enabled:

-For RS-422: 10 domes at a maximum distance of 1 km (3000 ft) on two 22 AWG shielded twisted pairs (STP)

-For SensorNet: 32 devices at a maximum distance of 1 km (3000 ft) on one 22 AWG unshielded twisted pair (UTP)

-For Manchester: 3 domes at a maximum distance of 1500 m (5000 ft) on one 18 AWG shielded twisted pair (STP)

-For AD-UTC1: Maximum distance per dome is 700 m (2300 ft) on 20 AWG RG59U cable

The features of the SpeedDome Ultra VII with EIS can be extended to outdoor environments via the SpeedDome Ultra Outdoor Housing. The outdoor housing, designed especially for the SpeedDome Ultra’s small, unobtrusive size, makes it the perfect protection for the dome. The housing now features a reinforced outdoor housing as standard and a heavy duty vandal resistant housing kit option.

Two Mounting Base Options

The housing/eyeball assembly twist locks into both

mounting bases. The I/O board base connects the

housing/eyeball assembly in one step. Power, communication

and video cables (or composite cable) are connected one

time to an I/O PC board in the mounting base, so the

assembly is simply twist locked onto the base. Service

and maintenance are easy and can be accomplished

without a ladder or lift via the installation/removal tool. The

I/O board mounting base supports four alarm inputs and

four alarm outputs as well as power and communication LEDs. The standard base connects the housing/eyeball assembly in two steps. First, power, communication and video cables (or composite cable) are inserted through the base and attached to the assembly. Then the assembly is connected to the base. The standard mounting base supports one alarm input and one alarm output. The installation/removal tool cannot be used to install this configuration.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with I/O Board

 

with Flying Lead

 

Mounting Base

 

Mounting Base

 

 

 

 

 

(Pigtail)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N U M B E R O F P R E S ET S

Controller or

 

 

 

 

 

 

 

Matrix Switcher

 

Protocol

 

Number of Presets

ADTT16E

 

SensorNet

 

96

 

 

 

 

 

RS-4222

 

4

 

MegaPower LT

 

AD-UTC

 

96

 

 

 

 

 

SensorNet

 

96

 

AD2150

 

Manchester

 

64

 

 

 

 

 

RS-4223

 

16

 

MegaPower 48 and

 

SensorNet

 

96

 

MegaPower 48 Plus

 

Manchester

 

64

 

 

 

 

 

RS-422

 

96

 

VM96

 

SensorNet

 

 

Unlimited

 

 

 

 

RS-422

 

 

Unlimited

MegaPower 168

 

SensorNet

 

64

 

 

 

 

 

Manchester

 

64

 

 

 

 

 

RS-422

 

64

 

 

 

 

 

RS-4223

 

16

 

MegaPower 1024

 

Manchester4

 

64

 

 

 

 

 

RS-4223

 

16

 

Third party interfaces

 

RS-485

 

96

 

 

 

 

 

 

 

 

 

 

 

2Using SensorNet-to-RS-422 Converter (model number RCSN422)

3Using RS-422 Code Distributor (model number AD2083-02B)

4Using Manchester Code Distributor (model number AD2091)

1This distance is for the AD-UTC data only. See cable manufacturers specifications for video capabilities.