American Standard 6065.121, 065.525, 6065.161 Troubleshooting Flow Charts, SEE , page 6 in manual

Models: 6065.162 6065.122 6065.121 6065.565 6065.161 065.525

1 10
Download 10 pages 43.36 Kb
Page 9
Image 9
SEE STEP 10, page 6 in manual

8

M968699 Rev. 1.3

UNIT DOES NOT FLUSH AT ALL SEE STEP 10, page 6in manual

IS STOP VALVE OPEN? TROUBLESHOOTING FLOW CHARTS NO Manual background OPEN VALVE

YES

LOOK FOR REPEATED

DOUBLE FLASH ON SENSOR Manual backgroundYESManual background INSTALL NEW BATTERY

NO

 

 

TRY MANUAL VALVE BUTTON;

NO

REPLACE PISTON KIT

WILL THE UNIT FLUSH?

YES

INSTALL NEW BATTERY

SEE STEP 10, page 6 in manual

DOES THE SENSOR FLASH

FOR THE FIRST 5 SECONDS? Manual background NOManual background REPLACE SENSOR

YES

 

 

RETRY AUTOMATIC FLUSH;

 

 

WAS IT SUCCESSFUL?

NO

REPLACE SOLENOID KIT

UNIT IS CONTINUOUSLY FLUSHING Manual backgroundManual background

 

 

 

 

 

 

MANUAL VALVE

 

 

PUSH MANUAL FLUSH

 

 

 

 

 

 

 

 

OBSTRUCTED.

 

 

BUTTON; DOES IT RETURN?

 

 

NO

 

 

 

 

CLOSE STOP VALVE

 

 

 

 

 

 

 

 

 

 

 

 

AND SERVICE

1. COVER SENSOR FOR 10 SECONDS

 

 

 

2. UNCOVER SENSOR FOR 10 SECONDS.

 

 

DOES THE UNIT STOP FLUSHING?

YES

RETRY AUTO FLUSH

 

 

NO

 

 

 

 

 

 

 

 

 

 

LOOK FOR REPEATED

 

 

YES

INSTALL NEW BATTERY

 

 

DOUBLE FLASH ON SENSOR

 

 

 

 

 

 

 

 

SEE STEP 10, page 6

 

 

NO

 

in manual

 

 

 

 

 

 

 

TEST SENSOR. DISCONNECT

 

 

 

 

GRAY FLAT WIRE FROM BATTERY

 

 

 

 

COVER AND RE-CONNECT. SENSOR

 

 

 

 

SHOULD FLASH FOR 5 SECONDS.

 

 

 

 

 

DOES IT FLASH?

 

NO

REPLACE SENSOR

 

 

YES

 

 

1.CLOSE STOP VALVE,

2.REPLACE SOLENOID KIT.

3.RE-ASSEMBLE AND INSTALL UNIT.

4.OPEN STOP VALVE.

UNIT WILL ONLY FLUSH MANUALLY Manual backgroundManual background

LOOK FOR REPEATED

DOUBLE FLASH ON SENSORManual backgroundYES Manual backgroundBATTERY LOW; REPLACE BATTERY

NO

SEE STEP 10, page 6

 

in manual

1.COVER SENSOR FOR 10 SECONDS

2.UNCOVER SENSOR FOR 10 SECONDS.

RETRY AUTOMATIC FLUSH.

DOES THE UNIT FLUSH?

NO

 

 

 

 

 

TEST SENSOR. DISCONNECT

 

 

GRAY FLAT WIRE FROM BATTERY

 

 

COVER AND RE-CONNECT. SENSOR

 

 

SHOULD FLASH FOR 5 SECONDS.

 

 

DOES IT FLASH?

NO

REPLACE BATTERY

 

 

SEE STEP 10, page 6

YES

 

in manual

RETRY AUTOMATIC FLUSH.

NO

CLOSE STOP VALVE,

REPLACE SOLENOID KIT.

RE-ASSEMBLE & INSTALL UNIT.

OPEN STOP VALVE.

TROUBLESHOOTING FLOW CHARTS

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Weekdays 8:00 a.m. to 6:00 p.m. EST IN MEXICO 01-800-839-12-00

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of AS America, Inc.

Page 9
Image 9
American Standard 6065.121, 065.525, 6065.161, 6065.565, 6065.122 Troubleshooting Flow Charts, SEE , page 6 in manual