American Standard 065.525, 6065.161, 6065.565 6INSTALL FLUSH VALVE a & 8b, 7ADJUST SUPPLY STOP Fig

Models: 6065.162 6065.122 6065.121 6065.565 6065.161 065.525

1 10
Download 10 pages 43.36 Kb
Page 6
Image 6
6INSTALL FLUSH VALVE; Fig. 8a & 8b

6INSTALL FLUSH VALVE; Fig. 8a & 8b

1.As shown in Fig. 8a, insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8a.

Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape.

2.Align the FLUSH VALVE (2) (Fig. 8b) directly above the DOWN TUBE (7) and VACUUM BREAKER COUPLING NUT (6). Make sure that GASKET (10) is installed.

Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for the 121mm (4-3/4) dimension. Fig. 8b.

3.Pull the DOWN TUBE (7) up to meet the threaded FLUSH VALVE CONNECTION (8) and hand tighten the VACUUM BREAKER COUPLING NUT (6). Align all components of the flush valve assembly. Fig. 8b.

4.Lightly tighten the COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT

(6) and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten couplings to make water tight connections. Fig. 8b.

7ADJUST SUPPLY STOP; Fig. 9

IMPORTANT: To avoid overflowing, the SUPPLY STOP

(3)must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. The fixture must be able to handle a continuous flow in case of a flush valve failure.

1.After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side, block the sensor with your hand for 10 seconds.

Remove your hand and listen for audible “click” from within the valve.

2.Remove COVER (2) from SUPPLY STOP (3).Turn on water supply 1/4 turn to 1/2 turn(CCW) and test for leaks. Note: Unit may flush for approximately 5 to 10 sec. when water is first turned on. If flow persists, turn water off and repeat step #1 above.

3.Actuate the FLUSH VALVE:

A)Cover sensor with hand for 10 seconds.

NOTE: Stand outside of sensor detection aera.

B)Remove hand from in front of the sensor; unit will flush in approximately 3 seconds.

4.Adjust SUPPLY STOP (3) after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed.

5.When adjustment is complete, replace COVER (2) and tighten to ensure vandal-resistance.

Fig. 8a

 

 

 

 

3

 

 

1

 

5

4

 

2

 

Fig. 8b

121mm,+13mm, -6mm

(4-3/4)(+1/2, -1/4)

 

7ADJUST SUPPLY STOP; Fig. 95 2 8 10

6

7

9

Fig. 9

1

REMOVE COVER

 

 

 

3

2

 

 

COUNTER-CLOCKWISE

 

 

OPENS CONTROL STOP

 

CLOCKWISE CLOSES

 

CONTROL STOP

 

5

 

M968699 Rev. 1.3

Page 6
Image 6
American Standard 065.525, 6065.161, 6065.565, 6065.121, 6065.122 6INSTALL FLUSH VALVE a & 8b, 7ADJUST SUPPLY STOP Fig