3 | TEST INSTALLED FITTING |
| PRESS HANDLE |
| |
|
|
| DOWN TO OPERATE |
| |
| Turn on water supplies and check connections for leaks. |
| 3 | ||
|
|
|
|
| |
| Remove AERATOR (1) with KEY (2) supplied. |
|
| ||
| Operate FAUCET by pressing down on HANDLE (3). Handle is |
|
| ||
| set for approximately 8 second operating cycle. |
|
| ||
| Replace AERATOR (1). |
| 1 |
| |
4 |
|
| 5 | 2 |
|
TO ADJUST CYCLE TIME | SERVICE |
| |||
|
|
| |||
| Remove HANDLE (1) by removing INDEX BUTTON (2) | Remove HANDLE (1). Refer to Step 4 for handle removal. | |||
| and SET SCREW (3) with a 2.5mm hex wrench. | Remove ACTUATOR ASSEMBLY (2). |
| ||
|
|
|
|
| |
| Pull off HANDLE (1). |
| Remove WASHER (3). Pull out VALVE ASSEMBLY (4) and | ||
|
|
|
| ||
| To increase cycle time, turn the gray PLASTIC | FILTER SCREEN (5). |
| ||
| ADJUSTING NUT (4) clockwise. |
| Inspect that VALVE ASSEMBLY (4), FILTER SCREEN (5) and | ||
|
|
|
| ||
| To decrease cycle time, turn the gray PLASTIC | VALVE SEAT (6) are clean and free from debris. VALVE | |||
| ASSEMBLY (3) and FILTER SCREEN (5) can be cleaned with | ||||
| ADJUSTING NUT (4) | ||||
| soap and water. |
| |||
|
|
|
|
| |
| Replace SET SCREW (3), INDEX BUTTON (2) and | Replace FILTER SCREEN (5) and VALVE ASSEMBLY (4). Place | |||
| HANDLE (1). Test faucet for proper operation and | ||||
| WASHER (3) on top of VALVE ASSEMBLY (4). Thread VALVE | ||||
| cycle time. |
|
| ||
|
|
| ACTUATOR (2) onto faucet. Torque VALVE ACTUATOR (2) | ||
|
|
|
| ||
|
|
|
| to |
|
|
| 3 |
| Replace HANDLE (1). |
|
|
|
|
|
| |
| 2 |
| 1 |
|
|
|
|
|
| 1 | |
|
|
|
|
| |
| 2.5mm HEX |
|
| REMOVE | REPLACE |
| WRENCH |
|
| ||
| TO DECREASE |
| TO INCREASE |
|
|
| CYCLE TIME |
| CYCLE TIME |
|
|
| ROTATE |
| ROTATE |
| 2 |
| COUNTER- | 4 | CLOCKWISE |
| |
| CLOCKWISE |
|
|
|
3
4
5
6
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
M 9 6 8 4 9 7 A