American Standard 2280, 2316, 2319 Install Toilet, Install Tank, Connect Water Supply, Adjustments

Models: 2262 2280 2319 2316

1 4
Download 4 pages 36.36 Kb
Page 2
Image 2
INSTALL TOILET

6

BOLT CAP

CLOSET FLANGE

CLOSET BOLT

WASHER NUT

INSTALL TOILET

a.Position toilet squarely to wall and, with a rocking motion, press bowl down fully on wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor.

!CAUTION:

DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b.Install caps on washers. (If necessary, cut bolt height to size before installing caps.)

c.Smooth off the bead of sealant around base. Remove excess sealant.

7a

For Tanks/Bowls using Speed Connect System (Tank mounting bolts pre-installed).

TANK MTG.

RUBBER

GASKET

BOLTS PRE-

 

INSTALLED

 

WASHER

NUT

INSTALL TANK

a.Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening, and tank mounting bolts go through mounting holes. Secure with metal washers and nuts.

b.With tank parallel to wall, alternately tighten nuts until tank is snugged down evenly against bowl surface.

!CAUTION:

DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT!

7b

For all other Tanks/Bowls

RUBBER

INSTALL TANK WASHER

RUBBER

TANK MTG. CONNECT WATER SUPPLY GASKET BOLTS

WASHER

NUT

INSTALL TANK

a.Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening.

b.Insert tank mounting bolts and rubber washers from inside tank, through mounting holes, and secure with metal washers and nuts.

c.With tank parallel to wall, alternately tighten nuts until tank is snugged down evenly against bowl surface.

!CAUTION:

DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT!

8

INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions.

 

9

TANK

CONNECT WATER SUPPLY

 

WATER INLET

 

a.

Connect water supply line between

 

 

WASHER

 

 

shutoff valve and tank water

COUPLING NUT

FLEXIBLE

 

inlet fitting. Tighten coupling nuts

SUPPLY

 

securely. Check that refill tube is

 

 

 

 

 

inserted into overflow tube.

 

VALVE NUT

b.

Turn on supply valve and allow

 

 

 

COMPRESSION

 

tank to fill until water rises to

 

 

shutoff position.

 

COLLAR

 

TRIM

 

c.

Check for leakage at fittings,

 

 

tighten or correct as needed.

PLATE

 

 

VALVE

10

OVERFLOW TUBE

TRIP LEVER

 

 

REFILL TUBE

 

Fig. 10A

WATER CONTROL

 

ASSEMBLY

 

WATER LINE LEVEL

 

 

FLUSH VALVE

 

FLOAT

 

FLAPPER

 

ASSEMBLY

WATER INLET

FLUSH VALVE

 

ADJUSTMENTS

a.Adjust water level. Water level should be adjusted to level indicated on tank by adjusting valve height.

See Step 11 for valve height adjustment method

b.If bowl fails to siphon, an adjustment may be required with the lift chain. Simply remove the bead chain from the retainment clip (see Fig. 10A) and take up slack on the chain, and reinsert on lift rod. Make sure the chain is not too taught.

TOILET REQUIRES THAT THE TANK REFILLS IN NO LESS THAN ONE MINUTE. ADJUST WATER SUPPLY VALVE (FIG. 9) ACCORDINGLY.