6
BOLT CAP
CLOSET FLANGE |
7
RUBBER
WASHER
RUBBER
TANK MTG. GASKET
BOLTS
WASHER
NUT
INSTALL TANK
CLOSET BOLT
WASHER NUT
INSTALL TOILET
a.Position toilet squarely to wall and, with a rocking motion, press bowl down fully on wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor.
!CAUTION:
DO NOT OVERTIGHTEN NUTS
OR BASE MAY BE DAMAGED!
b.Install caps on washers. (If necessary, cut bolt height to size before installing caps.)
c.Smooth off the bead of sealant around base. Remove excess sealant.
a.Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening.
b.Insert tank mounting bolts and rubber washers from inside tank, through mounting holes, and secure with metal washers and nuts.
c.With tank parallel to wall, alternately tighten nuts until tank is snugged down evenly against bowl surface.
! CAUTION:
DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT!
8 INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions.
9a | Before continuing, determine the type of water supply connecation you have from |
| the chart below and use the appropriate assembly parts required to properly |
| reconnect the water supply. DO NOT use plumber's putty to seal these fittings. |
METAL/COPPER | METAL FLANGED | METAL SPIRAL | VINYL/BRAIDED | |||
FLARED TUBING | TUBING | TUBING | CONNECTOR | |||
| LOCK NUT | LOCK NUT | LOCK NUT | LOCK NUT | ||
| CONE | EXISTING | EXISTING | COUPLING | ||
| WASHER | |||||
| WASHER | CONE | NUT | |||
|
|
| ||||
| COUPLING | EXISTING | WASHER |
|
| |
|
|
|
| |||
| COUPLING | COUPLING |
|
| ||
| NUT |
|
| |||
|
| NUT | NUT |
|
| |
| WATER | WATER | WATER | WATER | ||
| ||||||
These parts must be used as | Use existing | Use existing spiral | Captive cone | |||
illustrated to insure | coupling nut | cone washer. | washers already | |||
connection. Use of existing | and washer. | Fluidmaster cone | included. No | |||
coupling nut may result in |
|
| washer may not | additional washers | ||
water leakage. Water supply |
|
| seal completely on | needed. | ||
tube or pipe must extend at |
|
| spiral type supply |
|
| |
least 1/2" inside threaded |
|
| line. |
|
| |
shank of valve (does not apply |
|
|
|
|
| |
to flanged tubing). |
|
|
|
|
| |
|
|
|
|
| ||
| CAUTION: DO NOT USE |
| CAUTION: Overtightening of |
| ||
| CONE WASHER WITH |
| LOCK NUT or COUPLING NUT |
| ||
|
| could result in breakage and |
| |||
| PLASTIC SUPPLY LINE. |
| potential flooding. |
|
9b
With correct washers in place (see Step 9a), tighten COUPLING NUT 1/4 turn beyond hand tight. DO NOT OVERTIGHTEN.
- 2 - | |
|