WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS

WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

!WARNING: When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.

. Grounding is required. The unit should be installed by a licensed electrician and grounded. . Permit access for servicing motor as noted.

4. All building materials and wiring should be routed away from the pump body and heater (if equipped).

PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS:

GFCI CIRCUIT REQUIREMENTS:

FOR MODEL NUMBERS:

 

 

The whirlpool should be installed on a 120 vac, 15 amp dedicated

2351

GFCI circuit.

The circuit should be hard-wired from the electrical power supply panel. The

2371

circuit must be a three () wire circuit from the electrical supply panel. A

2383

grounded neutral wire and a third wire, earth ground, are essential.

 

Optional heater requires a separate 15 amp maximum GFCI circuit.

 

 

 

The whirlpool should be installed on a 120 vac, 20 amp dedicated

2466

GFCI circuit.

The circuit should be hard-wired from the electrical power supply panel. The

 

circuit must be a three () wire circuit from the electrical supply panel. A

 

grounded neutral wire and a third wire, earth ground, are essential.

 

Optional heater requires a separate 15 amp maximum GFCI circuit.

 

 

 

120 VAC

WHITE

 

BLACK

 

 

 

 

 

 

 

GND.

PUMP/MOTOR

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

WIRE SELECTION GUIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum distance from

 

 

 

fusebox to motor

 

Motor

 

 

 

 

 

 

50'

 

100'

150'

 

200'

Hi Performance

 

 

 

 

 

 

Rating

 

 

115V Power Line

 

2.1 H.P.,

 

 

 

 

 

 

 

 

 

1.4 H.P.,

12

 

10

8

 

8

and 1.25 H.P.

 

 

 

 

 

 

 

 

The sizes shown on this

chart are recommendations

for copper conductors only. Always follow local and national electrical codes

754407-100 Rev. B



Page 8