MAINTENANCE
When the Sensor detects a user, the water
immediately starts to flow. Water flow will stop Two
seconds after user is out of sensor range. The off delay
allows the user to comfortably move his hands without
the flow cycling on to off. As a precaution, a safety
timer will turn off the water, after the sensor has been
blocked for 59 seconds. The water will stay off until the
blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50mm - 250mm)
Default: Set at Factory 6" (150mm)
6

HAND WASH SENSOR OPERATION;

Fig. 1

1
1. Setting the Detection Zone (Distance):
Remove cover from ENCLOSURE. Disconnect GRAY
SENSOR WIRE (1) from circuit board, then reconnect.
2. While the SENSOR CONTROL LED (2) is blinking
slowly, place your hand 1 - 2 in. (30-50mm) in front of
the sensor. Fig. 2a.
3. When the LED stops blinking and stays "ON", move
your hand to the desired position and hold in place until
the LED begins to blink again. Fig. 2a.
4. Once the SENSOR CONTROL LED (2) begins to
blink again, remove your hand from the detec tion zone.
When the fla shing stops, th e detection di stance is set .

HOW TO CHANGE SENSOR

RANGE; (Factory set at 6") Fig. 2

2
Fig. 2
Fig. 2a
DETECTION
ZONE
Fig 1
1" - 2" (30mm - 50mm
BLINKING LED22
Fig. 2a Fig. 2a
BLINKING LED2
UP TO 10"
(250mm)
1. Remove AERATOR HOUSING (1) with KEY supplied
with faucet.
3. Remove AERATOR (2) from HOUSING (1).
2. Clean the AERATOR SCREENS (3) with a old tooth
brush to remove dirt.
4. Rinse Clean with water. Reassemble and install into
spout end. Be sure black seal washer is in place.

HOW TO CLEAN AND REMOVE

THE AERATOR; Fig. 3

3
2
3
1

Fig.3

M965274
1
Fig. 2