10 TEST INSTALLED FITTING

 

With HANDLES (1) in OFF position, turn on WATER

4

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3).

1

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3).

1

CHECK DRAIN CONNECTIONS

 

Operate POP-UP KNOB (4) and fill lavatory with water.

 

Check that DRAIN STOPPER (5) makes a good seal

 

and retains water in SINK. If DRAIN STOPPER (5)

3

does not seal properly, please refer to Troubleshooting

section in these instructions.

 

Release POP-UP KNOB (4) down and check all drain

 

connections and "P" trap for leaks. Tighten

 

if necessary.

5

 

WASTE

OUTLET

2

2“P” TRAP

11

SERVICE

1

2

 

 

To change direction of handle rotation, proceed as follows:

Turn valve to OFF position.

Remove IINDEX (1) and HANDLE SCREW (2).

Pull HANDLE (3) and ESCUTCHEON (4) off.

Remove ADAPTER (5) and SPRING CLIP (6).

3

4

Lift STOP WASHER (7), turn 90˚ and replace.

90˚

 

Replace SPRING CLIP (6).

 

Replace ADAPTER (5), ESCUTCHEON (4)

 

HANDLE (3), SCREW (2), and INDEX (1).

6

 

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

Remove AERATOR (8) and rinse clean if water flow becomes distorted.

5

7

8

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER.DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968786 Rev . 1 . 3

4

Page 4
Image 4
American Standard 2555.201 installation instructions Test Installed Fitting, Check Drain Connections, Service