COLONY™ 5 x 30 AFR

INTEGRAL APRON WITH REMOVABLE ACCESS PANEL

FOR ABOVE-FLOOR ROUGH INSTALLATION

HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS

2740.XXX SERIES

WHIRLPOOL/BATHING POOL INSTALLATION INSTRUCTIONS

7

 

 

(178mm)

3/4

C/L OF DRAIN

(19mm)

 

 

 

 

 

FINISHED

SEE FITTING WALL

SPECS FOR

DIMENSIONS

1-1/2 O.D.

TAILPIECE

29-7/8

(759mm)

C/L OF

SUPPLIES

HORIZONTAL TAILPIECE

ABOVE FLOOR OUTLET

1-1/2 (38mm)

59-7/8

(1521mm)

(1)AIR VALVE

(6)JETS

WATER RETENTION FLANGE (3 SIDES)

14-1/8

(359mm)

ON/OFF

SWITCH

PUMP

ACCESS TO PUMP/MOTOR THROUGH REMOVABLE FRONT ACCESS PANEL

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.

To insure maximum performance and pleasure from this product, please follow the instructions and cautions.

List of Required Components (not included):

• Drain 1583.470* • Bath Filler*

* see your American Standard Distributor

List of Required Tools and Supplies:

 

 

 

 

C/L OF

 

 

 

 

 

 

SHOWER ARM

 

 

 

 

 

 

FINISHED

 

 

OPTIONAL TO

 

 

 

WALL

 

 

7/8 WATER

 

 

C/L OF

 

 

FINISHED FLOOR

 

 

 

 

USUALLY BETWEEN

RETENTION

 

 

VALVES

 

 

65 & 78

FLANGE

 

 

 

 

 

(1651 & 1981mm)

(3 SIDES)

12

 

C/L OF

 

 

 

C/L OF

 

 

 

 

(305mm)

 

SPOUT

 

LEVELING

 

OVERFLOW

OPT.

4

 

 

 

 

 

STRINGER

 

3

 

TILING

 

 

(102mm)

 

NOT FOR

 

(76mm)

 

 

FLANGE

SUPPORT

 

 

 

 

 

 

TOP OF

 

 

 

 

 

UNDERSIDE

DECK

19-1/4

 

 

 

 

OF DECK

 

(489mm)

 

 

 

 

19

 

 

 

 

 

(483mm)

ROUGH

 

 

 

 

 

FLOOR

 

 

 

 

 

 

3-3/4

 

 

2-1/2

 

 

 

(95mm)

 

 

 

 

 

 

 

(64mm)

 

 

 

BATH SUPPORT

 

 

 

 

 

 

 

 

 

 

 

MATERIAL

 

 

 

 

 

GENERAL SPECIFICATIONS FOR 2740 WHIRLPOOL

INSTALLED SIZE

 

 

 

59-7/8 x 29-7/8 x 19-1/4 (1521 x 759 x 489mm)

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

105 Lbs. (47 Kgs.)

WEIGHT w/WATER

 

 

 

 

 

 

 

 

480 Lbs. (216 Kgs.)

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

 

45 Gal. (171 L)

WHIRLPOOL MIN. OPERATING VOL.

 

 

 

 

 

38 Gal. (144 L)

BATHING WELL AT SUMP

 

 

 

20 x 46 (508 x 1168mm )

BATHING WELL AT RIM

 

 

 

 

25-1/2 x 55-1/2(648 x 1410mm )

 

 

 

 

WATER DEPTH TO OVERFLOW

 

 

 

 

 

 

11-1/2 (292mm)

 

 

 

 

 

 

FLOOR LOADING

 

 

 

 

 

39 Lbs./Sq.Ft. (188 Kgs./Sq.m)

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

 

 

PTS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20.8

CUBE (FT3)

 

 

 

 

 

 

35.3

 

 

 

 

 

 

 

 

 

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP

 

 

 

 

 

 

 

 

 

 

 

 

1.1 HP, 9.9 AMPS,120V.

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL INSTALLATION INFORMATION

Bath may only be installed in a recess type installation.

Tools

Supplies

Level

Nails

• Tape Measure

• Putty

Pipe Wrench

Caulking (waterproof)

Slip Joint Pliers

1 x 3 or 2 x 2

Screw Driver

 

Stringers

Standard

Drop Cloth

 

Woodworking Tools

• 15 amp GFI

Personal Safety

 

Outlet

 

Equipment

Cement, Plaster,

• Caulking Gun

 

Grout

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.

After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.

If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others.

IMPORTANT:

Water test unit before installation and enclosure!

Locate studs as required. Insure rough dimensions are proper, plumb and square. For whirlpools, access to pump/motor may be made through access opening in apron panel. The following procedure must be used for all installations: leveling support stringer should be as indicated. This bath is not self-supporting and must be supported along it's entire bottom. Support with mortar or grout.

Position bathtub/whirlpool within the recess, check level, front to back, side to side, and shim as necessary.

To secure the tub to wood studs use drywall screws w/washers or roofing nails immediately above the flange of the tub. To secure the tub to steel studs use 4" drywall screws and flatwashers.

See page 2 for complete installation information.

Caution: Take extra care when driving nails or screws to avoid damaging the tub.

The tile or similar finished floor will be butted against the bottom of the tub apron, also holding the tub in place.

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

© AS America, Inc. 2008

752562-100 Rev. HAll product names listed herein are trademarks of AS America, Inc. unless otherwise noted.

Page 1
Image 1
American Standard 2740.XXX SERIES installation instructions Colony 5 x 30 AFR, General Installation Information