ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

The whirlpool and air massage versions should be installed on a 120 vac, 15 amp dedicated circuit. The combination system requires a 120 vac, 20 amp dedicated circuit. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER

REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.

ELECTRICAL INSTALLATION

FOR COMBINATION SYSTEM: SEPARATE 20 AMP GFCI OUTLET

FOR WHIRLPOOL OR AIR MASSAGE: SEPARATE 15 AMP GFCI OUTLET

120 VAC

 

WHIRLPOOL MOUNTED

 

 

AIR SWITCH OR

 

 

WALL TIMER

WHITE

BLACK

PUMP/MOTOR

GND.

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

753026-100 Rev. G

(3)

Page 3
Image 3