Installing Power Controller
The following illustration shows a Sun server configured through a serial port connection on the Digi CM 32.
Installing Power Controller
To connect the Digi RPM power controller to the Digi CM use the
If you are using any other manufacturer of power controllers, please refer to "About Serial Port Cabling" on page 143 for more information.
Before proceeding, plug the power controller into an appropriate power source and turn it on.
Note: The DIP switches on the Digi RPM are used for cascading. Make sure that the dip switches of the first unit are set to off. For more information about cascading refer to "Cascading Multiple Digi RPM Units" on page 100.
Configuring Power Controller
Only system administrators can add a power controller although authorized users may reconfigure outlets or serial ports.
Configure the serial port parameters to match the power controller
1.Log in to the Digi CM (username root, password dbps).
2.Click Serial port > Configuration.
3.Select the port number of the serial port you want to connect to the power controller.
4.Select the Serial port parameters:
Baud rate | 9600 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Flow control | None |
DTR behavior | High when open |
5.Click Save & apply.
6.Continue by adding the power controller.
92 | Chapter 12 |