User Access for Power Controller

Note: The screen above shows that serial port one on the Digi CM is connected to a Sun Server that is supplied power from outlets 1 and 2 on the power controller. In the example above, Gilligan has access to the power outlets.

7.To select the parameters for the User Access Control, click the User Access link. You may grant specific users permission to access an outlet or restrict access for specific users from an outlet. For more information see "User Access for Power Controller" on page 96.

User Access for Power Controller

The Digi CM can be configured to allow all users or specific users access to the power controller feature as well as restricting specific users to the power controller feature. User Access is configured on an outlet by outlet basis.

Note: User Access to a serial device that is connected to the power controller in configured under Serial Port > Configuration > Port # > User Access

Configuring to Allow Specific Users Access

To configure the Digi CM for specific users, you must deselect <<Everyone’s>> access and add the specific user and access as in the following steps.

1.Log in to the Digi CM (username root, password dbps)

2.Click Power Controller > Configuration > Outlets > Select the outlet # to configure.

3.Select the port to configure to the outlet. If it is a non-serial device select None.

4.Edit the outlet title. If there is a serial port, the port title will appear and cannot be edited from this screen.

5.Click Save & apply.

96

Chapter 12

Page 96
Image 96
Digi Digi CM manual User Access for Power Controller