Configuring SNMP

Configuring SNMP

To configure the Digi CM for SNMP do the following:

1.Access the Digi CM web interface.

2.Under the Network heading, choose SNMP configuration.

3.Fill in information for the MIB-II system objects section and choose Yes under EnableAuthenTrap. The fields are described in the following section:

sysContact - Identity of the contact person managing the MIB-II system.

sysName - The name identifying the system. By convention, this is the fully qualified domain name of the Digi CM unit. An example is: DigiCM@companyname.com.

sysLocation. - The physical location of the unit such as Room 264 or Engineering Lab.

sysService (Read only). - A series of values, separated by commas, indicating the set of services the system provides. By default the Digi CM only supports Application (7) service level.

EnablePowerOnTrap. - Determines whether the SNMP agent generates a trap each time the Digi CM is started.

EnableAuthenTrap. - Indicates whether the SNMP agent process is permitted to generate authentication failure traps.

EnableLinkUpTrap. - Determines whether the SNMP agent generates a trap each time the network connection comes up.

EnableLoginTrap - Determines whether the SNMP agent generates a trap for each login.

Note: Trap values override all other configuration information, meaning all other authentication failure traps can be disabled with this setting.

4.Enter Access control settings based on the following field descriptions:

IP Address - Defines what applications can access the Digi CM SNMP agent to exchange information and control actions. If no IP addresses are listed, any application can access the SNMP agent.

Community - The options are public or private. Permissions - The options are Read only or Read/Write.

54

Chapter 5

Page 54
Image 54
Digi Digi CM manual Configuring Snmp