Rackable Systems Management Card
.
| Field | Description |
|
|
|
|
|
| Control |
|
|
|
|
|
|
|
| The first column shows the current state. |
|
| Power status | Three buttons are available to initiate an action to either, power |
|
| on, power off or restart the server. Dependant on the current sta- |
| |
|
|
| |
|
| tus Power on or Power off is disabled. |
|
|
|
|
|
| Reboot | Reboot the Rackable Server by sending a 500ms reset signal to |
|
| the server. |
| |
|
|
| |
|
|
|
|
| Connect | Spawn the Java Telnet applet or the local Telnet/SSH application |
|
| to connect directly to the port. |
| |
|
|
| |
|
|
|
|
| LED Mgmt |
|
|
|
|
|
|
| LED | To control the LED in the front of the Rackable Server. |
|
| The first columns shows the current status of the LED. Three but- |
| |
| Management | tons are available to select the activity of the status LED: turn on, |
|
|
| turn off and blinking. Either of these buttons is disabled. |
|
|
|
|
|
| LCD Mgmt |
|
|
|
|
|
|
| Currently | Shows the message that is currently displayed on the LCD dis- |
|
| displayed |
| |
| play. |
| |
| message |
| |
|
|
| |
|
|
|
|
| Erase | This function clears the LCD display. |
|
| The saved message stays saved to flash. |
| |
|
|
| |
|
|
|
|
| Save | Save currently displayed message to flash memory. |
|
|
|
|
|
| Show saved | The first columns shows the current status: Yes or No. |
|
| This parameter defines which message is displayed upon startup |
| |
| LCD message |
| |
| of the server, either the saved message or the standard: “Rack- |
| |
| upon startup |
| |
| able Systems Phantom Vx.xx”. |
| |
|
|
| |
|
|
|
|
| Contrast | Set a contrast for the LCD panel. |
|
| The default is 50, the range is 0 – 100. |
| |
|
|
| |
|
|
|
|
| Phantom |
|
|
| Properties |
|
|
|
|
|
|
| Temperature | Indicates current temperature inside the Rackable Systems Server. |
|
|
|
|
|
| Power delay | Time in seconds before the server starts up after applying power |
|
|
| ||
|
|
| |
|
|
|
|
|
| The power sense option toggles between sensing server power |
|
|
| on the reset header or on the J7 connector. Most applications will |
|
| Power sense | use the “Reset” option. This option should be set before shipping |
|
|
| from Rackable Systems, but may need to be reset if somehow |
|
|
| changed after shipping. |
|
|
|
|
|
| Communication | Configure the baud rate used to communicate with the Rackable |
|
| settings | Systems Management Card. For this change to become effective |
|
| reset or |
| |
| Baud Rate |
| |
| switch the port settings in the Digi CM port settings. |
| |
|
|
|
|
|
|
|
|
Chapter 10 | 83 |