CADET™ 5' x 32"
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
2770.XXXW SERIES
WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
222mm
19 mm (3/4)
FINISHED
EEFITTING WALL PECS FOR MENSIONS
806mm
403 mm
C/L OF
SUPPLIES
PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 1521 mm
305 mm
(12)
OUTLINE OF CUTOUT 1483 mm x 768 mm
ON/OFF
SWITCH
229mm
(9)
| CUTOUT IN FLOOR | PUMP |
|
| |
| FOR DRAIN |
|
60mm |
| (2) AIR VALVES |
(8) JETS |
|
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
•Tile Bead Kit
•Apron Kit*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler* * see your American Standard Distributor
C/L OF DRAIN | C/L OF |
| ||
|
|
| SHOWER ARM |
|
OPTIONAL TO |
|
|
|
|
INISHED FLOOR |
|
| C/L OF |
|
SUALLY BETWEEN |
|
|
| |
1651 & 1981mm |
|
| VALVES |
|
(65 & 78) |
|
|
|
|
C/L OF |
|
| C/L OF |
|
OVERFLOW |
| 305 mm |
| |
38 mm | (12) | SPOUT | ■ LEVELING | |
| ||||
102 mm |
| STRINGER | ||
70mm |
|
| ||
|
| NOT FOR | ||
| (4) |
| ||
|
| SUPPORT | ||
|
|
| ||
|
|
|
| |
502 mm |
|
|
|
|
|
|
| 464 mm | |
ROUGH |
|
|
| |
|
|
|
| |
FLOOR |
|
|
|
|
INTEGRAL |
|
|
| |
SUPPORT |
| THREADS | 70 mm |
|
FEET |
| |||
| 117 mm | |||
|
|
| ||
|
|
|
GENERAL SPECIFICATIONS FOR 2770 WHIRLPOOL
INSTALLED SIZE |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (1521mm x 806 mm x 502mm) | |||||||
WEIGHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 85 Lbs. (39 Kg.) | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
WEIGHT w/WATER |
|
|
|
|
|
|
|
|
|
|
|
| 535 Lbs. (243 Kg.) | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
GAL. TO OVERFLOW |
|
|
|
|
|
|
|
|
|
|
|
|
| 54 Gal. (204 L.) | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
MIN. OPERATING GAL. |
|
|
|
|
|
|
|
|
|
| 49 Gal. (186 L.) | ||||||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||||||
BATHING WELL AT SUMP |
|
|
|
|
| 20 x 40 In. (508mm x 1016mm) | |||||||||||||||||
|
|
|
|
| |||||||||||||||||||
BATHING WELL AT RIM |
|
| |||||||||||||||||||||
|
| ||||||||||||||||||||||
WATER DEPTH TO OVERFLOW |
|
|
|
|
|
| 14 In. (356mm) | ||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
FLOOR LOADING |
|
|
|
|
|
|
| 41 Lbs./Sq. Ft. (197 Kgs/Sq. m.) | |||||||||||||||
|
|
|
|
|
|
| |||||||||||||||||
(PROJECTED AREA) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
PTS. |
|
|
|
|
|
|
| 15.6 | |||||||||||||||
|
|
|
|
|
|
| |||||||||||||||||
CUBE (FT3) |
|
|
|
|
| 29.6 | |||||||||||||||||
|
|
|
|
| |||||||||||||||||||
| WHIRLPOOL ELECTRICAL SPECIFICATIONS | ||||||||||||||||||||||
SYSTEM I PUMP |
|
|
|
|
|
|
|
| 1.1 HP, 9.9 AMPS, 120V. | ||||||||||||||
|
|
|
|
|
|
|
|
List of Required Tools and Supplies:
Tools | Supplies | ||
• | Level | • | Nails |
• | Tape Measure | • | Putty |
• | Pipe Wrench | • | Caulking (waterproof) |
• | Slip Joint Pliers | • | 1 x 3 or 2 x 2 |
• | Screw Driver |
| Stringers |
• | Standard | • | Drop Cloth |
| Woodworking Tools | • | 15 amp GFI |
• | Personal Safety |
| Outlet |
| Equipment | • | Cement, Plaster, |
• | Caulking Gun |
| Grout |
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
NOTE: Deck-mounted fittings are not recommended.
WARNING! Do not lift whirlpool by the piping har-
FOR
© American Standard Inc. 2003