11 INSTALL HANDLES (Lever)

11 INSTALL HANDLES (Lever)

Turn HANDLE STEM (1) to "OFF" position.

Place the HANDLE ADAPTER (2) on the HANDLE STEM (1).

Install the ADAPTER SCREW (3) and tighten securely. Position LEVER HANDLE (4) and place on ADAPTER (2).

Install the HANDLE SCREW (5) and tighten securely with hex wrench supplied.

55INSTALL HANDLES (Acrylic)

4

3

2

1

INSTALL HANDLES (Acrylic)

Turn HANDLE STEM (1) to "OFF"

 

position.

4

Place the ACRYLIC HANDLE (2)

 

on the HANDLE STEM (1).

3

Install the HANDLE SCREW (3)

 

and tighten securely.

 

Push in INDEX BUTTON (4).

2

 

1

12 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.12 TEST INSTALLED FITTING

Operate both HANDLES (1) to flush water lines thoroughly.

Rotate TRANSFER VALVE (5) from rim wash to spray several times to check operation.

13 CHECK DRAIN CONNECTIONS

OUTLINE OF BIDET

3

1

1

Pull up POP-UP KNOB (3) and fill Sink with water. Check

that DRAIN STOPPER (4) makes a good seal and retains4 water in Bidet. If STOPPER (4) does not seal properly,

please refer to “Troubleshooting Guide” in these instructions.

Push POP-UP KNOB (3) down and check all drain connections and "P" trap for leaks. Tighten

if necessary.

2

2

SPRAY

14 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

SERVICE

15 To change direction of handle rotation, proceed as follows:

Turn VALVE to OFF position.

Loosen HANDLE SCREW (1) .

Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER SCREW (4) and pull off ADAPTER (3).

Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3) catches on the other FLAT on VALVE STEM (5).

Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2). Tighten HANDLE SCREW (1).

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

113 CHECK DRAIN CONNECTIONSSERVICE