2 MAKE WATER SUPPLY CONNECTIONS
NOTE: FLEXIBLE SUPPLIES HAVE TO BE PURCHASED SEPARATELY
Carefully bend COPPER SUPPLIES to meet water supply lines using the palms of the hands to avoid kinking.
Connect HOT water supply line to left tube, and COLD water supply line to right tube using appropriate connectors.
Use 1/2" IPS FLEXIBLE SUPPLIES (3) or 3/8" O.D.
COPPER SUPPLIES TUBES
34
FERRULE
HOT
COLD
3 INSTALL SPRAY HOLDER
On model with separate spray, place the SPRAY HOLDER (1) into the appropriate mounting hole. Assemble the SPRAY HOLDER WING NUT (2) onto the shank of SPRAY HOLDER (1) from below and tighten. Do not use putty.
On model with spray through the ESCUTCHEON (3), place SPRAY HOLDER (4) into the hole of ESCUTCHEON (3). Assemble SPRAY HOLDER NUT (5) onto the shank of SPRAY HOLDER (4) from below and tighten. Do not use putty.
For installation less spray cap off SPRAY HOSE CONNECTION with PIPE CAP (6).
SPRAY HOSE
CONNECTION
43
56
4 CONNECT HOSE SPRAY
Feed SPRAY HOSE (1) through SPRAY HOLDER (2) and attach COUPLING NUT (3) of HOSE (1) to HOSE ADAPTOR (4) on valve body. Tighten COUPLING NUT (3) firmly.
1
2
1
2
4
3
M 9 6 8 1 8 8 E