2 POP-UP DRAIN

2 POP-UP DRAIN

Remove CLEAR PLASTIC COVER (1).

Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).

Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B.

Fig. A.

1Fig. A.Fig. B.3 REMOVE FLANGE

3INSTALL DRAIN FROMREAR OF SINK5 TIGHTEN LOCKNUT

2

Fig. B.

BELOW FIXTUREDRAIN

BODY

4

3 REMOVE FLANGE

Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A.

Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B.

Fig. A.

1

2

Fig. B.

4

3

4

INSTALL DRAIN FROM

 

REAR OF SINK

5 TIGHTEN LOCKNUT

BELOW FIXTURE

 

 

From under side of SINK

4

 

Tighten LOCKNUT (1) firmly with Adjustable

 

install DRAIN BODY (1) up

 

Wrench or Channel Locks.

 

through drain outlet.

 

 

 

 

Note: No plumber’s putty

 

DRAIN

 

 

 

OUTLET

 

 

or caulk is required.

3

 

 

 

The CABLE ATTACHMENT

 

 

 

 

POINT (2) must face towards

 

 

 

 

the rear of the SINK.

 

1

1

 

Install FOAM GASKET (3) and

 

 

 

2

 

 

FLANGE (4) onto drain body

 

 

 

from above SINK and tighten

 

 

 

 

FLANGE (4) firmly.

 

 

 

6 FLANGE GASKET AND POP-UP KNOB

Fig. A.

Fig. B.

 

 

 

 

DOWN

 

Check DRAIN FLANGE in SINK to ensure that

 

1

 

WHITE FOAM GASKET (3) is fully compressed

 

 

 

 

 

and not visible. Fig. A.

 

 

 

 

POP-UP KNOB (1) must be fully down. Fig. B.

WHITE FOAM

 

 

 

 

GASKET

DRAIN

 

 

 

NOT VISIBLE

FLANGE

43167 Rev. 1 . 3