INSTALL FAUCET WITHOUT ESCUTCHEON PLATE

(4101.115 with soap dish) (4101.350 less soap dish)

Insert SEAL WASHER (1) into ESCUTCHEON (2). Place ESCUTCHEON (2) onto sink or mounting surface. Insert supply HOSES (3) and SHANK (4) through ESCUTCHEON (2) and mounting surface.Make sure slot in fitting base aligns with tab on ESCUTCHEON (2). Figure 1.

Assemble RUBBER WASHER (5), BRASS WASHER (6) and threaded LOCKNUT (7) onto SHANK (4) from underside of sink or mounting surface. Hand tighten LOCKNUT (7) and check that rotation of HANDLE (8) from HOT to COLD is centered.

Use a screwdriver to tighten SCREWS (9) on LOCKNUT (7). Work your way around LOCKNUT (7), tightening the SCREWS (9) slightly each time until all are snug to ensure even pressure.

Install SPOUT ASSEMBLY: Insert SEAL WASHER (1a) into ESCUTCHEON (2a). Insert HOSE (10) and SHANK (11) through ESCUTCHEON (2a) and mounting surface. Make sure slot in spout base aligns with tab on ESCUTCHEON (2a).

Figure 2.

Assemble RUBBER WASHER (5a), BRASS WASHER (6a), and threaded LOCKNUT (7a) onto SHANK (11) from underside of sink or mounting surface. Hand tighten LOCKNUT (7a). Use a screwdriver to tighten SCREWS (9a) on LOCKNUT (7a) the same as fitting installation above.

(4101.115 with soap dish) Push SOAP DISH (11) into SOAP DISH SHANK (12). Insert SOAP DISH ASSEMBLY into mount hole. From underside of counter assembly LOCKNUT (13) onto SOAP DISH SHANK (12).

Align SOAP DISH (11) and tighten LOCKNUT (13).

8

Figure 1

Figure 2

SLOT

4

 

ALIGN SLOT

 

3

AND TAB

 

ALIGN SLOT

 

TAB

SLOT

2

AND TAB

 

 

 

1

11

 

 

 

 

 

TAB

11 Manual background

2a Manual background

5

12

1a

 

6

 

 

 

 

 

 

7

 

 

 

9

5a

6a

 

13

 

 

 

7a

 

 

9a

10

 

 

 

2 MAKE WATER SUPPLY CONNECTIONS

 

 

Turn off hot and cold water supplies before beginning.

 

 

Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies. Connection on fitting

 

supplies are 3/8" compression. Connect left supply (Marked with a Red Stripe)

2

to Hot and right supply (Marked with Blue Stripe) to Cold wall supply. Use adjustable

wrench to tighten connections. Do not over tighten.

 

1

 

 

 

Faucet supplies are 21" long from faucet base.

 

 

Note: If additional supply length is required, installer must purchase

 

HOT

those parts separately.

 

 

COLD

Important: If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.