2 MAKE WATER SUPPLY CONNECTIONS
Turn off hot and cold water supplies before beginning. |
| |
Connect FLEXIBLE SUPPLIES (1, 2) directly |
| |
to wall supplies. Connection on fitting |
| |
supplies are 3/8" compression. Connect |
| |
left supply (Marked with a Red Stripe) to Hot |
| |
and right supply (Marked with Blue Stripe) to | 2 | |
Cold wall supply. Use adjustable wrench to | ||
| ||
tighten connections. Do not over tighten. | 1 | |
| ||
Faucet supplies are 21" long from faucet base. |
| |
Note: If additional supply length is | COLD | |
| ||
required, installer must purchase | HOT | |
additional parts separately. | ||
Important: If SUPPLY HOSES (1, 2) are |
| |
too long, loop as illustrated to avoid kinking. |
| |
3 INSTALL WEIGHTS |
| |
With HAND SPRAY (1) seated in FAUCET (2), |
| |
install WEIGHTS (4) onto HOSE (3) using two |
| |
SCREWS (5). Locate the WEIGHTS (4) two feet (2') | 2 | |
from the underside of the sink deck. | ||
Tighten SCREWS (5) firmly. |
| |
Install SEAL WASHER (6) into COUPLING NUT (7). | 1 | |
Tighten COUPLING NUT (7) to HOSE END (3a). |
|
4 TEST INSTALLED FAUCET
Move HANDLE (1) down into "off" position.
Turn on water supplies.
Check connections for leaks.
(See Section 5)
1
With HANDLE (1) down in "off" position, unthread SPRAY FACE (3) from SPRAY (2).
Operate handle up and down, in COLD and HOT positions, to flush water lines thoroughly.
Replace SPRAY FACE (3) onto SPRAY (2).
24"
73a 6
3
4 5
2
3
REMOVE
Check HAND SPRAY (2) operation:
With faucet on pull SPRAY FACE (3) down to switch from stream to spray.
2
3
PULL SPRAY FACE (3)
DOWN TO SWITCH FROM
STREAM TO SPRAY
M968986 Rev. 1. 3