5 CHECK CONNECTIONS FOR LEAKS.

5 CHECK CONNECTIONS FOR LEAKS.

Move HANDLE down into "off" position.

Turn on water supplies and check connections for leaks.6 SERVICE

Operate HANDLE (2) up and down, left and right to flush water lines thoroughly.

Operate HAND SPRAY and check connections for leaks. Clogged CARTRIDGE outlets or inlets may cause reduced flow.

CHECK CONNECTIONS

FOR LEAKS HOT LIMIT SAFETY STOP ADJUSTMENT

6 SERVICE

If faucet drips, operate HANDLE several times from "off" to "on." Do not apply excessive force.

FLOW CONTROL DEVICE may accumulate dirt. To remove the FLOW CONTROL DEVICE, unthread SPRAY AND HOSE ASSEMBLY and rinse clean FLOW CONTROL DEVICE.

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

7 CARE: Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3).

Manual background Unthread the ESCUTCHEON CAP (4). Unthread three MOUNTING SCREWS (5).

Manual background Lift CARTRIDGE (6) off MANIFOLD (7) and remove CARTRIDGE SEALS (8).

Manual background Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).

Manual background Place SEALS (8) into CARTRIDGE PORTS (6A).

Manual background Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING SCREWS (5) alternately.

Manual background Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE SCREW (1) and install INDEX BUTTON (2).

HOT LIMIT SAFETY STOP ADJUSTMENT

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.

Remove HANDLE BUTTON (1) and loosen SET SCREW (2). Pull HANDLE (3) off valve stem. Pull off CAP (4). Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (5). Follow Step "A" or "B" to adjust min./max.

discharge temperature. "0" being the hottest to "7" the coldest SPRAY AND HOSE ASSEMBLY

temperature setting. Factory set at "0".

Replace ESCUTCHEON CAP (4), HANDLE (3), tighten

"A"

PRY RED RING FORWARD

HANDLE SCREW (1) and install INDEX BUTTON (2).

AND ROTATE COUNTER-

 

CLOCKWISE ONE CLICK

2Manual backgroundManual backgroundManual backgroundManual background 3

1Manual background

Manual backgroundManual background 4

5

Manual backgroundManual background 6

6A Manual backgroundManual backgroundManual background 8

7

FLOW CONTROL

DEVISE

TEMPERATURE

SETTING NUMBERS

"B"

PRY RED RING FORWARD

AND ROTATE CLOCKWISE "B" "B"

ADJUSTMENT WHEN

WATER IS TOO COLD

 

 

"A"

"A"

 

 

 

1

0

 

ADJUSTMENT WHEN

2

 

 

WATER IS TOO HOT

4

 

 

3

 

 

 

5

 

 

6

6

 

 

5

"RED RING"- HOT LIMIT SAFETY STOP

7 CARE:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.