American Standard 4332.100.XXX installation instructions Test Installed Faucet

Models: 4332.100.XXX

1 4
Download 4 pages 10.67 Kb
Page 3
Image 3
TEST INSTALLED FAUCET

4

TEST INSTALLED FAUCET

5

2

3

 

 

Move HANDLE (1) into "off" position.

1

 

Unthread SPRAY HOSE (3) from SPRAY (2).

Turn on water supplies and check connections for leaks.Manual background

Hold HOSE END (3) in sink and operate HANDLE (1) on and off, hot and cold to flush water lines thoroughly. Replace SPRAY (2).

Pull SPRAY (2) out and check hose and supply connections

for leaks. Check that SPRAY HOSE (3) and WEIGHT (4) slide up and down freely and do not interfear with supplies or waste outlet plumbing. With faucet on turn SPRAY TOP (5) to spray and aerator fuctions.

Check all drain connections for leaks. Manual background

Move HANDLE (1) to "off" position.

Manual backgroundManual background 4Manual backgroundManual backgroundManual backgroundManual backgroundManual background 3Manual background

HOT & COLD SUPPLIES

5 SERVICE

 

Clogged CARTRIDGE outlets or inlets may cause reduced

 

flow. To clean, first turn off water supply then:

 

Loosen and remove LEVER HANDLE (1). Loosen HANDLE

 

SCREW (2) with 2.5mm Hex Wrench and then pull HANDLE

 

BASE (3) off.

11

Unthread ESCUTCHEON CAP (4). Unthread the

CARTRIDGE NUT (5).

Remove CARTRIDGE (6). Clean inlets of CARTRIDGE (6) and MANIFOLD (7).

Reassemble CARTRIDGE (6). Replace CARTRIDGE

NUT (5), CAP (4) and HANDLE assembly, check flow.

If SPOUT (11) leaks at swivel point the O-RINGS (12) need

REMOVE

INSTALL

12

10 3mm HEX WRENCH 1

CLEAN 5

4

7

2

 

to be replaced. To remove SPOUT (11):

Disconnect SPRAY HOSE (8) from CONNECTING NUT (9).

Loosen the SPOUT SET SCREW (10) with a 3mm Hex wrench.

Rotate the SPOUT (11) side to side while pulling upward to remove SPOUT (11) from faucet body. Remove SPRAY HOSE (8).

Replace the defective parts and grease O-RINGS (12). Replace SPRAY HOSE (8). Push SPOUT (11) back into position. Tighten SET SCREW (10). Reconnect SPRAY HOSE (8) to CONNECTING NUT (9).

Check that SPOUT (11) rotates freely and does not leak at the swivel point.

6

Manual backgroundManual background 9 Manual backgroundManual backgroundManual background 8

3Manual background

6 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968578 Rev . 1 . 1

Page 3
Image 3
American Standard 4332.100.XXX installation instructions Test Installed Faucet