2 MAKE WATER SUPPLY CONNECTIONS
Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES (1, 2) directly |
| |
to wall supplies. Connection on fitting |
| |
supplies are 3/8" compression. Connect |
| |
left supply to Hot (Marked with a Red Tag) |
| |
and right supply to Cold wall supply. Use |
| |
adjustable wrench to tighten connections. | 2 | |
Do not over tighten. | ||
| ||
Faucet supplies are 21" long from faucet base. | 1 | |
|
Note: If additional supply length is
required, installer must purchaseCOLD additional parts separately.
HOT
Important: If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.
3 INSTALL SPRAY HOLDER
On model with separate spray, place the SPRAY HOLDER (1) into the appropriate mounting hole. Assemble the SPRAY HOLDER WING NUT (2) onto the shank of SPRAY HOLDER (1) from below and tighten. Do not use putty.
On model with spray through the ESCUTCHEON (3), place SPRAY HOLDER (4) into the hole of ESCUTCHEON (3). Assemble SPRAY HOLDER NUT (5) onto the shank of SPRAY HOLDER (4) from below and tighten. Do not use putty.
For installation less spray cap off SPRAY HOSE CONNECTION with PIPE CAP (6).
SPRAY HOSE
CONNECTION
43
56
4 CONNECT HOSE SPRAY
Feed SPRAY HOSE (1) through SPRAY HOLDER (2) and attach COUPLING NUT (3) of HOSE (1) to HOSE ADAPTOR (4) on valve body. Tighten COUPLING NUT (3) firmly.
1
2
1
2
4
3
M968202 REV . 1 . 2