American Standard 4454, 4453 installation instructions 3 4

Models: 4453

1 4
Download 4 pages 25.1 Kb
Page 3
Image 3
3
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
TEMPERATURE SETTING NUMBERS

5

TEST INSTALLED FAUCET

 

 

 

 

Move HANDLE down into "off" position and remove AERATOR.

 

 

 

 

 

 

 

 

Turn on water supplies and check connections for leaks.

 

 

 

 

 

 

 

 

Operate HANDLE up and down, left and right to flush water

A E R AT O R

 

 

 

 

 

 

lines thoroughly.

 

 

 

For faucet with spray, direct SPRAY HEAD into sink and

 

 

 

 

 

 

 

 

activate SPRAY. Check hose connections for leaks.

 

 

 

 

Move HANDLE down to "off" position and replace AERATOR.

 

 

 

 

 

 

 

 

 

CHECK CONNECTIONS

FOR LEAKS Manual background

6 SERVICE

Reduced flow. If the flow gradually reduces over a number of months, the AERATOR may have collected debris. To clean, remove AERATOR and rinse with water and remove any debris. Turn on faucet to wash any debris out of the faucet. Thread AERATOR back into spout. Operate faucet.

Spout leakage. If fitting leaks above or below SPOUT HUB remove SPOUT as follows and check SPOUT O-RINGS and SPACER O-RINGS.

Remove HANDLE BUTTON (2) and loosen SET SCREW (1). Pull HANDLE (3) off valve stem.

1 Manual background

2

3

4

5

6

Remove CAP (4) and and RETAINER (5). Loosen CARTRIDGE SCREWS (6) and

12

7

remove CARTRIDGE (7).

 

 

Pull off SPACER (8) and O-RINGS (9).

Remove SPOUT (12) by pulling up gently while moving SPOUT (12) side to side.

Check both SPOUT O-RINGS (11). Replace if necessary.

A E R AT O R

 

8

9

On models with SPRAYS, DIVERTER (10) can be cleaned by pulling

SPOUT

DIVERTER (10) out of the MANIFOLD (13). Clean DIVERTER (10) and

HUB

MANIFOLD (13). Push DIVERTER (10) back into MANIFOLD (10).

11

Reverse procedure to reinstall SPOUT, CARTRIDGE and HANDLE.

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

13

To clean, first turn off water supply then:

Remove PLUG BUTTON (2), loosen HANDLE SCREW (1) and remove HANDLE (3).

Remove ESCUTCHEON CAP (4). unscrew the three CARTRIDGE SCREWS (6).

Clean inlets of CARTRIDGE (7) and MANIFOLD (13).

Manual backgroundManual backgroundManual backgroundManual background10

Reassemble CARTRIDGE (7), alternately tightening SCREWS (6). Replace CAP (4) and HANDLE (3). Check flow.

HOT LIMIT SAFETY STOP ADJUSTMENT

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.

Remove HANDLE BUTTON (1) and loosen SET SCREW (2). Pull

 

HANDLE (3) off valve stem. Pull off CAP (4). Use a flat blade

"B"

screwdriver or your fingers to pull up and rotate red

 

HOT LIMIT SAFETY STOP (5). Follow Step "A" or "B" to adjust

 

min./max.discharge temperature. "0" being the hottest to

"B"

"7" the coldest temperature setting. Factory set at "0".

 

ADJUSTMENT WHEN

Replace ESCUTCHEON CAP (4), HANDLE (3), tighten

WATER IS TOO COLD

 

HANDLE SCREW (1) and install INDEX BUTTON (2).

 

"A"

PRY RED RING FORWARD

AND ROTATE COUNTER-

CLOCKWISE ONE CLICK

 

 

 

 

 

"A"

"A"

 

 

 

 

 

 

 

 

 

 

0

 

ADJUSTMENT WHEN

 

 

 

1

 

 

 

4

 

2

 

 

 

WATER IS TOO HOT

3

 

 

 

 

5

 

 

 

 

 

 

6

 

 

 

 

 

6

"B"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

"RED RING"- HOT

 

 

 

 

 

LIMIT SAFETY STOP

M968202 REV . 1 . 2

Page 3
Image 3
American Standard 4454, 4453 installation instructions 3 4