6 ATTACH CABLE CONNECTOR

Fig. A.

Fig. B.

Thread CABLE CONNECTOR (1) clockwise

 

 

onto DRAIN BODY CONNECTION (2) and

 

1

hand tighten. Fig. A.

 

 

 

Your new POP-UP DRAIN installation is

 

 

now complete. Fig. B.

 

 

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

 

 

Fig. B.

 

 

 

 

1-1/4” O.D.

 

 

2

7CHECK OPERATION OF POP-UP

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and

1

closes. Fig. B.

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

2

8MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE

PURCHASED SEPARATELY.

Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE

SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).

Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.

1/2" PIPE

1

THREAD

 

2

COUPLING

NUT

FLEXIBLE

 

SUPPLIES

 

 

3

3/8 O.D.

 

BULL-NOSE

 

RISERS

 

3/8” COMPRESSION

COMPRESSION

CONNECTION

NUT

 

FERRULE

HOTCOLD

M 9 6 8 6 8 8

3

Page 3
Image 3
American Standard 6044.XXX Attach Cable Connector, Check Operation of POP-UP, Make Water Supply and Waste Connections