American Standard 6054.XXX 9TEST INSTALLED FITTING, Check Drain Connections, Service

Models: 6054.XXX

1 7
Download 7 pages 8.59 Kb
Page 4
Image 4
9TEST INSTALLED FITTING

9TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.CHECK DRAIN CONNECTIONS

Remove AERATOR (3). Turn counter-clockwise to remove.

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3). Turn clockwise to install.

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.

Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks. Tighten

if necessary.

4

 

1

1

 

10 SERVICE3

5

WASTE

OUTLET

2

“P” TRAP 2

10 SERVICE

To change direction of handle rotation, proceed as follows:

Turn Hot and Cold supplies off to faucet. Turn HANDLES to OFF position.

Remove PLUG BUTTONS (1) on either side of ESCUTCHEON (2). Loosen SET SEREWS (3) with 2.5mm hex wrench.

Pull SPOUT up while rotating side to side and remove

 

SPOUT & HANDLE (4) assembly to expose VALVES (7).

6

 

Remove SPRING CLIP (5) from valve .

Lift STOP WASHER (6), turn 90˚ and replace.

Replace SPRING CLIP (5).

Align SPOUT & HANDLE (4) assembly and install onto valve body. When handles and spout are properly seated and aligned tighten SET SCREWS (3) and replace PLUG BUTTONS (1).

AERATOR (8) may accumulate dirt causing distorted and reduced water flow. Remove AERATOR (8) and rinse clean. Turn counter-clockwise to remove.

4

90˚

8

 5 711 CARE INSTRUCTIONS: 5 7

1 Manual backgroundManual backgroundManual background

3 Manual background 2

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

2.5mm Hex wrench

11 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M 9 6 8 6 3 2

4

Page 4
Image 4
American Standard 6054.XXX 9TEST INSTALLED FITTING, Check Drain Connections, Service, Care Instructions