FAQ'S

Q:How will I know if battery needs to be replaced?

A:Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.

Q:Why has the flow rate of the faucet reduced significantly?

A:Check and clean aerator and strainer.

Q:There is no flow out of faucet when I'm in the sensor range?

A:Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1800-442-1902.

Q:Why does the faucet operate the opposite of expected-Turns On when not in sensor range, but turns off when in sensor range?

A:Sensor wires to solenoid are reversed. Black to - & Red to + is correct.

Q:What is the normal operating pressure range?

A:Faucet will operate with supply pressures ranging from 20-80 psi.