American Standard 7010.901 installation instructions Installation Instructions, Green Tea

Models: 7010.901 7010.900

1 4
Download 4 pages 3.46 Kb
Page 1
Image 1
Installation

Installation

Instructions

GREEN TEA

7010.900

DECK-MOUNT BATH FILLER

7010.901

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1M

M968595 Rev . 1 . 2

Recommended Tools

ROUGHING-IN DIMENSIONS

Flat Blade Screwdriver

10-5/8"

GREEN TEA ADJ. 6-1/2 TO 12 7010.900

*Wrench

Adjustable Wrench

Channel Locks

*Hex key *Supplied with Fitting

MOUNTING

SURFACE

DECK-MOUNT BATH FILLER7010.901 2-9/16" Manual backgroundManual background

Manual background 8-1/16"Manual background

5-5/16"2-1/8"Manual background

3-3/4"

3"

 

1-1/8 DIA.Manual backgroundManual backgroundManual backgroundManual backgroundManual background

3/4-14 MALE

(H)

N.P.T. INLETS

 

1-1/16 DIA.

7-7/8"

(200mm)

 

2-1/16"

2-1/16

 

DIA.

 

DIA.

 

 

1-1/4

 

1-1/2 MAX.

MAX.

 

3

 

 

 

Manual backgroundManual backgroundManual backgroundManual backgroundManual background1-3/16 DIA. (C)

12 MAX

1 SPOUT ASSEMBLY

CAUTION

Turn off hot and cold water

supplies before beginning.

Install RING WASHER (1) into SPOUT recess. Check that O-RING (2) on end of SPOUT SHANK (3) is in place. Insert SPOUT SHANK (3) through center hole on mounting surface.

Assemble RUBBER WASHER (4) and BRASS WASHER (5) and LOCKNUT (6) onto SPOUT SHANK (3). Align SPOUT ASSEMBLY and from underside of ledge secure SPOUT ASSEMBLY into position with LOCKNUT (6).

SPOUT

ASSEMBLY

Manual backgroundSPOUT RECESS

1

3 Manual backgroundManual background 2

MOUNTING

SURFACE

4

5

6

2 PREPARE TUBE AND TEE ASSEMBLY

Prepare TUBE and TEE ASSEMBLY (1) to fit center to center VALVE (2) location (between 6-1/2" and 12"). If necessary, cut and/or bend TUBING carefully. Make sure tube bend is close to the TEE (1) so that it will not effect the compression joint at the VALVE CONNECTION.

Remove COUPLING NUT (3) and FERRULE (4) from each VALVE (2) and slide onto TUBING (5).

4

3

1

5

3

4

Manual background ADJ. 6-1/2 TO 12Manual background

MOUNTING

SURFACE

2

NOTE VALVE inlet is 3/4-inch NPT male.

Page 1
Image 1
American Standard 7010.901 installation instructions Installation Instructions, Green Tea, 7010.900, Deck-Mountbath Filler