American Standard 8871 installation instructions Fig. A

Models: 8871

1 6
Download 6 pages 60.05 Kb
Page 3
Image 3
Manual background

7

ATTACH CABLE CONNECTOR

 

 

 

 

 

Fig. A.

 

 

Fig. B.

 

 

 

Thread CABLE CONNECTOR (1) clockwise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

onto DRAIN BODY CONNECTION (2) and

 

1

 

 

 

 

 

 

hand tighten. Fig. A.

 

 

 

 

 

 

 

 

 

 

 

 

Your new POP-UP DRAIN installation is now complete. Fig. B.

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

Fig. B.

2

Manual background 1-1/4” O.D.

8

CHECK OPERATION OF POP-UP

 

 

1

 

 

 

 

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and

 

 

 

 

 

 

 

 

 

 

 

 

closes.

 

 

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

Manual background 2

9 MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED

AND MUST BE PURCHASED SEPARATELY.

Thread TEE BODY (4) to SPOUT SHANK (5).

Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).

Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE

 

 

 

SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use

 

 

 

 

adjustable wrench to tighten connections. Do not over tighten.

 

 

 

Be careful not to kink copper supply when bending. Use tubing

 

 

1A

cutter to cut to proper length.

 

 

 

Connect HOT water supply to inlet of left SHANK and COLD

 

 

5

7A

 

 

6A

water supply to right SHANK using sealant, appropriate

 

 

 

connectors, and COUPLING NUTS.

 

 

 

COUPLING

 

 

 

 

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

 

 

 

NUT

1

 

 

 

waste outlet.

7

4

 

 

 

3

1/2" PIPE THREAD

6

 

 

 

 

 

3/8 O.D.

 

 

 

 

 

 

 

 

BULL-NOSE

COMPRESSION

 

2

 

RISERS

 

 

NUT

 

FLEXIBLE

 

 

 

COLD

FERRULE

 

 

SUPPLIES

 

HOT

 

3/8 COMPRESSION

 

 

 

CONNECTION

 