10 INSTALL HANDLES

CAUTION

Turn off hot and cold water

supplies before beginning.

 

See separate instruction sheet supplied with handle kit for handle installation.

11 TEST INSTALLED FITTING

With VALVE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3).

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3).

12 CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Sink. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks. Tighten

if necessary.

TO CLEAN AERATOR

AERATOR (3) may accumulate dirt causing distorted and reduced water flow. Unscrew and remove AERATOR (3) and rinse clean.

Replace AERATOR (3) and operate handles several times from OFF to ON position. Do not force, handles turn only 90˚.

5

1

1

3

4

WASTE

OUTLET

2

HOT

COLD

 

 

“P” TRAP

2

13 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

14 SERVICE

90˚

To change direction of handle rotation,

2

proceed as follows:

 

Turn valve to OFF position.

 

Remove INSERT and HANDLE SCREW.

 

Slip HANDLE with ADAPTER off.

 

Remove SPRING CLIP (1).

1

Lift STOP WASHER (2), turn 90° and replace.

Replace SPRING CLIP (1).

Replace ADAPTER, HANDLE, SCREW, and

INSERT.

AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90°.

M966230 Rev. 1.2

4

Page 4
Image 4
American Standard 8871 installation instructions 90˚