American Standard T980.712 EverClean Finish Care Instructions, Valve Trim, Install Handles

Models: T980.722 T980.712 T980.732 T980.702

1 2
Download 2 pages 14.13 Kb
Page 2
Image 2
2 VALVE TRIM

2 VALVE TRIM

Place the ESCUTCHEON SEALS (1) over the VALVE BODIES (2).

Thread the VALVE ESCUTCHEONS (3) into the VALVE BODIES (2). Align the HANDLE STEM (4) with the SLEEVE (5) as necessary. Thread the VALVE ESCUTCHEON (3) into the BODIES (2) until the ESCUTCHEON (3) contacts the finished deck.

3

4

1

5

2

3 INSTALL HANDLES

 

 

 

LEVER HANDLE

 

CROSS HANDLE

 

 

 

 

Turn VALVE into OFF position.

 

Turn VALVE into OFF position.

6

Push ADAPTER (1) into HANDLE (2)

5

Push ADAPTER (1) into

4

in a way that the male square on the

3

HANDLE BASE (2).

 

ADAPTER (1) fits in the female square

5

of the HANDLE (2).

 

Push HANDLE BASE (2)

 

 

 

Push HANDLE (2) and ADAPTER (1)

 

and ADAPTER (1) onto

2

onto VALVE STEM (4).

2

VALVE STEM (3).

 

 

 

Check alignment, if not satisfactory aligned;

 

Push CROSS (4) onto

1

Push out ADAPTER (1) carefully.

1

ADAPTER (1).

 

 

 

Assemble and tighten

 

Turn ADAPTER (1) either 45˚ or 90˚

 

3

so that male square on ADAPTER (1)

 

HANDLE SCREW (5).

catches different female square in

4

Push INDEX CAP (6) in

 

HANDLE BASE (2).

 

 

Assemble and tighten HANDLE

 

top of HANDLE (4).

 

 

 

 

SCREW (3).

 

 

 

Push INDEX CAP (5) in top of HANDLE (2).

4

 

5

SERVICE

 

3

1

 

TESTING

 

 

2

 

 

 

 

To change the direction of handle rotation

 

 

 

Turn the HOT HANDLE (1) clockwise and the

 

Turn off the water supplies

 

 

 

 

 

 

 

4

 

 

COLD HANDLE (2) counterclockwise to the

 

Turn HANDLE (1) to the off position.

 

 

off position.

 

Remove the INDEX CAP (2) and the HANDLE

 

 

 

 

 

 

Unscrew and remove the SPOUT END (3).

 

SCREW (3). Pull the HANDLE BASE (4) off and

 

 

Slowly turn on the water supplies.

 

remove ADAPTER (5).

 

5

 

 

 

Unscrew the VALVE ESCUTCHEON (6).

 

 

 

 

 

 

 

 

Operate the HANDLES (1, 2) to flush water

 

Unscrew the VALVE LOCK NUT (7) and

6

 

 

lines thoroughly. Check SPOUT (4) connection

 

 

 

for leakage.

 

remove. A 17mm deep socket is required.

 

 

 

 

 

 

 

 

 

Turn the Handles off. Replace the SPOUT

 

Remove the CARTRIDGE (8) by

 

90$

 

 

 

pulling up on the SLEEVE (9).

 

7

 

 

END (3).

 

12

 

 

 

 

Remove the SCREW (10)

11 10

 

 

2

 

from the CARTRIDGE (8).

 

 

 

 

Remove the SPRING CLIP (11).

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

Remove the STOP WASHER (12).

 

 

 

3

 

Turn it 90˚ and replace.

 

 

 

 

 

Replace the SPRING CLIP (11).

 

8

 

 

 

 

 

 

1

 

 

 

 

 

 

 

Reverse the above steps to

 

 

 

 

 

 

 

 

 

 

4

 

reassembly the components.

 

 

 

 

 

 

If the spout drips, operate the handles several

 

 

 

 

times from the off to the on position. Do not

 

4 EverClean™ Finish Care Instructions

 

force - the handles only turn 90˚

 

 

 

 

 

 

 

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface. M968655 Rev. 1 . 1

Page 2
Image 2
American Standard T980.712, T980.702 EverClean Finish Care Instructions, Valve Trim, Install Handles, Service, Testing