10. General Safety Information

SCALDING HAZARD. If the water temperature is over 120°F, household members can suffer serious or fatal scalding and painful and permanent injury. • The Consumer

Products Safety Commission recommends an initial setting of 120°F, but advised that a slower response time of infants, aged, disabled and other persons increases the scalding hazard and may require lower settings. • Always check the water temperature before use, including washing, bathing or showering. • Temperature limiting valves are available from your plumbing supplier. A check valve must be installed in the boiler return line to prevent gravity flow through the heat exchanger. This can cause overheating and result in serious or fatal scalding.

SCALDING HAZARD. If the thermostat is not working properly or if this product is not installed in accordance with the manual, water temperature can reach excessive levels

that may cause serious or fatal scalding. After installation and any servicing of the unit, verify that the thermostat is working and firmly inserted in the thermostat well by following the thermostat testing instructions in the manual.

Failure to use the correct replacement parts may make your product unsafe.

In limited circumstances, space heating can be lost in the home with unit utilizing priority mode. Any demand for space heating is postponed until the water heater­has reached its set temperature. This delay in supplying the space heating zones is usually not noticed by the inhabitants of the living spaces. However, in the event of certain malfunctions such as circulator or thermostat failure, space heating could be delayed indefinitely. If undetected and uncorrected, freezing damage to piping could result.

If a steel hydropneumatic tank is in place, replace it with a properly sized diaphragm expansion tank. Otherwise, significant heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system has a diaphragm expansion tank and the boiler temperatures are being changed, resize the expansion tank.

If installing on city water supply, a properly sized thermal expansion tank is required with the water heater and should be installed as set forth­ in the product installation manual. Contact your water supplier or local plumbing inspector for additional information.

Prevent pressure build-up in any existing internal tankless coil. Do not plug incoming or outgoing tappings in the internal tankless coil plate. Leave the coil in the boiler and

leave system connections open to prevent pressure build-up.

Electrocution hazard. The water heater must be electrically grounded. Electrical supply must come from the boiler side of boiler’s emergency shut-off switch in order to prevent

unsafe boiler operation.

Chlorine Aggressive Water: The water quality can significantly influence the life of this Product. You should test for corrosive elements, acidity, total solids and other relevant contaminants, including chlorine and treat your water appropriately to insure satisfactory performance and prevent premature failure.

Note: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current copies of the Product Manual can be obtained at the place of purchase. Use proper safety equipment when installing.

EXPLOSION HAZARD. The pressure of the heat transfer medium must be limited to a maximum of 30 psig by an approved safety or relief valve on your boiler. The water heater

pressure must be limited to 150 psig maximum by the installation of a temperature and pressure relief valve (included). The relief tube must be plumbed to a suitable drain per code. No reducing coupling or other restriction may be placed in this line.

This Product, like most Products under pressure, may over time corrode, weaken and burst or explode, causing serious or fatal injury, leaking or flooding and/or property damage. To minimize risk, a licensed professional must install and periodically inspect and service the Product. A drip pan connected to an adequate drain must be installed if leaking or flooding could cause property damage. Do not locate in an area where leaking could cause property damage to the area adjacent to the appliance or to lower floors of the structure.

EXPLOSION OR RUPTURE HAZARD. A relief valve must be installed to prevent pressure in excess of local code requirement or maximum working pressure designated in the Product Manual, whichever is less. Do not expose Product to freezing temperatures or temperatures in excess of the maximum rated operating temperature.

If not installed by the boiler manufacturer, install a low water cut-off or pressure reducing valve on your boiler so that leaking will not result in a dry boiler which if the boiler

continues to fire, will cause an explosion hazard.

This unit must be installed as a separate heating zone. Do not connect this unit to an existing heating zone or feed boiler water directly through the coil as dangerous over-heating

will result.

Do not drain this appliance before shutting off the

supply valve and opening the relief valve or another downstream fixture, as it will damage this unit. A vacuum breaker should be installed to avoid damaging the liner. Damage to the unit and leakage can occur if a vacuum breaker is not installed.

USE GLYCOL ONLY WITH DOUBLE-WALLED HEAT EXCHANGER MODELS. Avoid risk of ingesting a toxic glycol fluid. The heat transfer medium should be water. If glycol must be used, it should only be used with double-walled heat exchangers and closely monitored for leakage.

CALIFORNIA PROPOSITION 65 WARNING! This product contains a chemical known by the State of California to cause cancer and to cause birth defects or other reproductive harm. (California Installer/Contractor - California law requires that this notice be given to consumer/end user of this product.) For more information: www.amtrol.com/prop65.htm

As in all plumbing products and water storage vessels, bacteria can grow in this Product, especially during times of non-use. Consult your local plumbing professional regarding any steps you may wish to take to safely disinfect your home’s plumbing system.

EXPLOSION OR RUPTURE HAZARD! A relief valve must be installed to prevent pressure in excess of local code requirement or maximum working pressure designated in the Product Manual, whichever is less. At least once every 3 years or if discharge is present, a licensed contractor should inspect the temperature and pressure relief valve and replace if corrosion is evident or the valve does not function. FAILURE TO INSPECT THIS VALVE AS DIRECTED

COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD-UP WHICH CAN RESULT IN PRODUCT FAILURE, SERIOUS INJURY OR DEATH AND/OR SEVERE PROPERTY DAMAGE AND VOID THE PRODUCT WARRANTY.

-10-

Page 10
Image 10
Amtrol HM-80L, HM-41Z, HM-80Z, HM-41L warranty General Safety Information

HM-41Z, HM-80L, HM-80Z, HM-41L specifications

Amtrol is a well-regarded name in the world of water heating and thermal expansion tanks. Among its offerings, the HM-41L, HM-80Z, HM-80L, and HM-41Z models stand out for their exceptional design and innovative technologies. These tanks are engineered to ensure optimal performance and reliability in both residential and commercial applications.

The HM-41L is particularly notable for its compact design, making it ideal for installations in areas with limited space. Its reinforced steel construction ensures durability while the advanced coatings provide superior corrosion resistance. This model features Amtrol's unique expansion technology, which allows for efficient management of thermal expansion in water heating systems, preventing damage to plumbing and fixtures.

On the other hand, the HM-80Z and HM-80L models cater to higher capacity requirements. Both units are designed with a high-efficiency insulation system that minimizes heat loss, thereby improving energy efficiency and reducing operating costs. The HM-80Z variant is equipped with a zinc-coated exterior for added durability against environmental factors, making it suitable for outdoor installations. The HM-80L, meanwhile, retains the traditional finish but also boasts improved thermal performance.

The HM-41Z model combines compactness with versatility. It is engineered to handle a diverse range of hot water applications, from standard residential setups to commercial uses. Like its counterparts, it incorporates Amtrol's advanced expansion technology, ensuring safety and efficiency. Its robust design and materials guarantee a long lifespan, making it a worthy investment for any property.

A key feature across all these models is Amtrol's commitment to quality and safety. Each tank undergoes rigorous testing to meet industry standards, ensuring reliability in performance. Additionally, the user-friendly installation process and compatibility with various heating systems make these tanks an excellent choice for both new constructions and retrofits.

Overall, the Amtrol HM series—HM-41L, HM-80Z, HM-80L, and HM-41Z—brings together cutting-edge technology, durability, and energy efficiency. Their versatile applications and robust designs make them standout options in thermal expansion tank solutions. These models not only protect plumbing systems but also enhance the overall efficiency of hot water systems, offering peace of mind to homeowners and professionals alike.