Programming
22 Color Passive-Matrix LCD Touch Panels
System Send_Commands (Cont.)
BEEP
Gives an output of
one beep.
The Beep button in the Protected Setup page must be set from 1 - 10 for the BEEP com-
mand.
Syntax:
"’BEEP’"
Example:
SEND_COMMAND TP,"’BEEP’"
Beeps the panel if the Beep button is not set to 0.
BRIT
Adjusts brightness
of display.
Syntax:
"’BRIT-<level>’"
Variab les:
level = 1 - 5 (1 = minimum; 5 = maximum)
Example:
SEND_COMMAND TP,"’BRIT-5’"
Sets to highest brightness level.
CONT
Adjusts brightness
of display.
Syntax:
"’CONT-<level>’"
Variab les:
level = 1 - 12 (1 = minimum; 12 = maximum)
Example:
SEND_COMMAND TP,"’CONT-12’"
Sets to highest brightness level.
CALIBRATE
Starts touch panel
calibration.
Syntax:
"’CALIBRATE’"
Example:
SEND_COMMAND TP,"’CALIBRATE’"
Starts the calibration operation on the touch panel.
CLOCK
Sets the time and
date.
Syntax:
"’CLOCK <mm-dd-yy> <hh:mm:ss>’"
Variab les:
mm = 01 - 12, dd = 01 - 31, yy = 00 - 99
hh = 00 - 23, mm = 00 - 59, ss = 00 - 59
Example:
SEND_COMMAND TP,"’CLOCK 02-08-98 19:16:00’"
Sets the touch panel’s date to February 8, 1998, and time to 7:16 p.m.
DBEEP
Gives a double
beep output.
This command only works if the Double Beep value in the Protected Setup page is set to
ON.
Syntax:
"’DBEEP’"
Example:
SEND_COMMAND TP,"’DBEEP’"
Double beeps the panel.
MOUSE
Turns on the
Microsoft Serial
Mouse.
Syntax:
"’MOUSE’"
Example:
SEND_COMMAND TP,"’MOUSE’"
Activates the Microsoft Serial Mouse.