,", SEND_COMMAND TP, "@BOR,65,11", "@ENA,,, SEND_COMMAND TP, "@ENA,128,1", "@FON,,""> AMX 8.5" Color Passive LCD Touch Panels Shorthand Variable Text Commands (Cont.)
Programming
37
Color Passive-Matrix LCD Touch Panel
Shorthand Variable Text Commands (Cont.)
@BOR
Sets the border
style on a button.
Syntax:

"’@BOR’,<variable text address>,<border style>"

Variab les :
variable text address = 1 - 255
border style = See theBorder Styles and Programming Numbers table on page 26.
Example:

SEND_COMMAND TP, "’@BOR’,65,11"

Sets the border style to Double shadow on button 65.
@ENA
Enables/Disables
buttons based on
their variable text
channel.
Syntax:

"’@ENA’,<variable text address>,<disable button on/off>

Variab les :
variable text address = 1 – 255
disable button on/off:
1 = button disabled
0 = button enabled
Example:

SEND_COMMAND TP, "’@ENA’,128,1"

Disables the button with variable text channel 128. This button will stop responding to
pushes completely, until it is sent an Enable command. Nothing short of a touch panel
Softrom firmware reload will re-enable the button. Reloading the touch panel file, reloading
the Axcess program, or resetting power on the panel or master, will not re-enable the but-
ton. It must be sent an Enable command once it has been Disabled.
@FON
Sets the text font
on a button.
Syntax:

"’@FON’,<variable text address>,<font style>"

Variab les :
variable text address = 1 - 255
font style = See theFont Styles and Programming Numbers table on page 26.
Example:

SEND_COMMAND TP, "'@FON',56,32"

Sets the text on button 56 to variable font style 32.
@ICO
Assigns an icon to
a button.
Syntax:

"’@ICO’,<variable text address>,<icon>"

Variab les :
variable text address = 1 - 255
icon file number = 1 - 255
Example:

SEND_COMMAND TP,"’@ICO’,16,12"

Adds icon 12 on button 16.